Page 7

BSPP Generator

2.Slide axle through both axle mounting brackets on cradle frame, as shown in Figure 1.

3.Slide a wheel over the axle.

NOTE: Be sure to install both wheels with the air pressure valve on the outboard side.

4.Slide a flat washer over the axle and place the e-ring onto the groove in the axle.

5.Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e-ring. Seat the e-ring by pressing the pliers closed.

6.Repeat step 3 through 5 to secure second wheel.

7.Remove the temporary blocks.

8.Attach the vibration mounts to the support leg with 1/4-20 x 3/4” capscrews and 1/4-20 lock nuts.

9.To aid support leg assembly, rest generator on cradle, engine end down. Remove the existing hardware from the left unit vibration mount with 13mm wrench. Use the same hardware to attach the support leg.

10.Attach the other side of the support leg with a M8 x 20 mm cap screw and M8 lock nut. Rest generator on wheels and support leg.

11.Attach handles to handle brackets on generator frame, as shown in Figure 1, with M8 x 45 mm capscrews, flat washers, nylon washers, and M8 lock nuts.

NOTE: Be sure to install the nylon washers between the handle brackets on the generator frame and the brackets on the handle assembly.

12.Loop handle pins to generator frame as shown in Figure 1. Raise handles and insert handle pins to move generator.

13.Check each fastener to ensure it is secure and the tires are inflated between 15-40 PSI.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.

NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

Add Fuel

NOTE: This gasoline engine is certified to operate on

gasoline. Exhaust Emission Control System: EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane with equipment. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

BEFORE STARTING THE ENGINE

Add Engine Oil

Place generator on a level surface.

Refer to engine owner’s manual and follow oil recommendations and instructions.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to fill above the baffle.This allows adequate space for fuel expansion (Figure 2).

Figure 2 — Typical Fuel Expansion Space

TANK

Baffle

FUEL

4.Install fuel cap and wipe up any spilled fuel.

7

Image 7 Contents
PRO6500 01933 Safety Rules Table of ContentsEquipment Description When Transporting or Repairing Equipment When Adding or Draining Fuel When Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Remove Generator From Carton AssemblyInstall Wheel Kit Carton ContentsAdd Engine Oil When Adding FuelBefore Starting the Engine Add FuelGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStopping the Engine Connecting Electrical LoadsOperating Generator Starting the EngineTo recharge 12 Volt batteries, proceed as follows Charging a BatteryCold Weather Operation Operating Automatic Idle ControlPermanent Cold Weather Shelter Remove shelter when temperatures are above 40F 4CVolt AC, 30 Amp Locking Receptacle Wire Cord SetReceptacles 120/240 Volt AC, 30 Amp, Locking ReceptacleVolt DC, 10 Amp Receptacle Volt AC, 20 Amp, Duplex ReceptacleTest Gfci Circuit Breaker Ground Fault ProtectionDuring Generator Use Example Power ManagementDont Overload Generator CapacityGenerator Maintenance SpecificationsGeneral Maintenance Recommendations Engine MaintenanceEngine Storage Other Storage Tips Generator CleaningStorage Generator StorageProblem Cause Correction TroubleshootingYear Consumer Use Years Years orAvertissement Symboles de Danger et MoyensTable DES Matières Description DE L ÉquipementLorsque Léquipement Fonctionne Le générateur produit une tension élevéeLors DE Lajout OU DE LA Vidange DU Carburant Lors DU Démarrage DE LéquipementLorsque Vous Réglez OU Réparez Votre Générateur Unintentional peut résulter dans feu ou électriqueLors DE Tests Dallumage DU Moteur Arrêteur d’étincelles Connaissez Votre GénérateurEnlever le générateur de la boite Installe la Roue la TrousseFaites linstallation comme indiqué ci-après Figure AssemblageAjoutez de lessence Installez le bouchon à essence et essuyez lessence déverséeAvant LE Démarrage DU Moteur Ajoutez de lhuile à moteurBranchement au système électrique dun édifice Emplacement de la GénératriceUtilisation DE LA Génératrice Mise à la terre du systèmeArrêt du Moteur Utilisation DU GénérateurDémarrage du Moteur Branchement des Charges ÉlectriquesFonctionnement du Contrôle Automatique du Ralenti Fonctionnement PAR Temps FroidRecharge d’une Batterie Vent Abri Permanent Pour Temps Froids240V 120V Neutre Prises DE CourantPrise à Verrouillage de 120/240 Volts c.a., 30 Ampères Prise à Verrouillage de 120 Volts c.a., 30 AmpèresPrise de 10 Ampères, 12 Volts c.c Volts c.a., 20 Ampères Prise de Courant DoubleMise à lessai du disjoncteur Gfci Protection contre les fuites de terrePendant le fonctionnement de la génératrice Exemple NE PAS Surcharger GénérateurCapacité Gestion de la ConsommationEntretien du Générateur Recommandations Générales D’ENTRETIENSpécifications Entretien du MoteurRemisage du Moteur RemisageNettoyage de Générateur Remisage du GénérateurDépannage Garantie Limitée Instrucciones DE Seguridad Tabla DE ContenidosDescripción DEL Equipo AdvertenciaCuando Opere EL Equipo PeligroCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Voltios AC a 30 Amperios, monofásica de 60 Hz Conozca SU GeneradorTomacorriente Gfci Dobles de 120 Voltios AC, 20 Amp Tomacorriente con Dispositivo de Seguridad deContenido de la Caja MontajeInstale EL Juego DE Ruedas Para Retirar el Generador de la CajaRetire los calzos provisionales Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorParado Del Motor Operando EL Generador PrecauciónEncienda el Motor Conexion De Cargas ElectricasFuncionamiento del Control Automático de Marcha en Vacío Operación Durante UN Clima FríoCarga de la Bateria Figura 35 Refugio Frío Permanente del Tiempo 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Receptáculos PrecauciónTomacorrientes de 120 Voltios AC, 30 Amperios Tomacorrientes de 12 Voltios DC Volt AC, 20 Amperios, Receptáculo DoblesCompruebe el Disyuntor Gfci Protección Contra Fallos de Conexión a TierraMientras se Utiliza el Generador Ejemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaMantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorAlmacenando el Motor AlmacenamientoAlmacenando el Generador Para Limpiar el GeneradorNotas Diagnositicos DE Averías Problemo Accion CausaGarantía Limitada