Briggs & Stratton PRO6500 owner manual Table of Contents, Equipment Description, Safety Rules

Page 2

BSPP Generator

TABLE OF CONTENTS

Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

EQUIPMENT

DESCRIPTION

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.

This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by the engine.

This generator incorporates GFCI (Ground Fault Circuit Interrupter) outlet protection and has its neutral bonded to ground to pass OSHA inspections on job sites.This generator will not function when connected to a transfer switch since the home or building main breaker box also has a neutral bonded to ground.When both the generator and the home or building breaker box contains a neutral bonded to ground, the generators GFCI will open and no outlets will function.

WARNING

DO NOT remove the neutral bond.

Removing the neutral bond could result in death, bodily injury and/or property damage.

CAUTION! DO NOT exceed the generator’s wattage/amperage capacity. See “Don’t Overload Generator”.

Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice.

The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.

SAFETY RULES

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol () is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

WARNING

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Hazard Symbols and Meanings

Electrocution

Electrical Shock

Electrical Shock

Toxic Fumes

Explosion

 

Fire

Explosive Pressure

Chemical Burn

Hot Surface

 

Kickback

2

Image 2 Contents
PRO6500 01933 Equipment Description Table of ContentsSafety Rules When Operating Equipment When Adding or Draining FuelWhen Starting Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Carton Contents AssemblyInstall Wheel Kit Remove Generator From CartonAdd Fuel When Adding FuelBefore Starting the Engine Add Engine OilSystem Ground Using the GeneratorConnecting to a Building’s Electrical System Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Stopping the EngineOperating Automatic Idle Control Charging a BatteryCold Weather Operation To recharge 12 Volt batteries, proceed as followsRemove shelter when temperatures are above 40F 4C Permanent Cold Weather Shelter120/240 Volt AC, 30 Amp, Locking Receptacle Wire Cord SetReceptacles Volt AC, 30 Amp Locking ReceptacleVolt AC, 20 Amp, Duplex Receptacle Volt DC, 10 Amp ReceptacleDuring Generator Use Ground Fault ProtectionTest Gfci Circuit Breaker Capacity Power ManagementDont Overload Generator ExampleEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator MaintenanceGenerator Storage Generator CleaningStorage Engine Storage Other Storage TipsTroubleshooting Problem Cause CorrectionConsumer Use Years Years or YearDescription DE L Équipement Symboles de Danger et MoyensTable DES Matières AvertissementLors DU Démarrage DE Léquipement Le générateur produit une tension élevéeLors DE Lajout OU DE LA Vidange DU Carburant Lorsque Léquipement FonctionneLors DE Tests Dallumage DU Moteur Unintentional peut résulter dans feu ou électriqueLorsque Vous Réglez OU Réparez Votre Générateur Connaissez Votre Générateur Arrêteur d’étincellesAssemblage Installe la Roue la TrousseFaites linstallation comme indiqué ci-après Figure Enlever le générateur de la boiteAjoutez de lhuile à moteur Installez le bouchon à essence et essuyez lessence déverséeAvant LE Démarrage DU Moteur Ajoutez de lessenceMise à la terre du système Emplacement de la GénératriceUtilisation DE LA Génératrice Branchement au système électrique dun édificeBranchement des Charges Électriques Utilisation DU GénérateurDémarrage du Moteur Arrêt du MoteurRecharge d’une Batterie Fonctionnement PAR Temps FroidFonctionnement du Contrôle Automatique du Ralenti Abri Permanent Pour Temps Froids VentPrise à Verrouillage de 120 Volts c.a., 30 Ampères Prises DE CourantPrise à Verrouillage de 120/240 Volts c.a., 30 Ampères 240V 120V NeutreVolts c.a., 20 Ampères Prise de Courant Double Prise de 10 Ampères, 12 Volts c.cPendant le fonctionnement de la génératrice Protection contre les fuites de terreMise à lessai du disjoncteur Gfci Gestion de la Consommation NE PAS Surcharger GénérateurCapacité ExempleEntretien du Moteur Recommandations Générales D’ENTRETIENSpécifications Entretien du GénérateurRemisage du Générateur RemisageNettoyage de Générateur Remisage du MoteurDépannage Garantie Limitée Advertencia Tabla DE ContenidosDescripción DEL Equipo Instrucciones DE SeguridadCuando Ponga EN Funcionamiento EL Equipo PeligroCuando Añada Combustible O Vacíe EL Depósito Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Tomacorriente con Dispositivo de Seguridad de Conozca SU GeneradorTomacorriente Gfci Dobles de 120 Voltios AC, 20 Amp Voltios AC a 30 Amperios, monofásica de 60 HzPara Retirar el Generador de la Caja MontajeInstale EL Juego DE Ruedas Contenido de la CajaAgregue Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Retire los calzos provisionalesUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioConexion De Cargas Electricas Operando EL Generador PrecauciónEncienda el Motor Parado Del MotorCarga de la Bateria Operación Durante UN Clima FríoFuncionamiento del Control Automático de Marcha en Vacío Figura 35 Refugio Frío Permanente del Tiempo Tomacorrientes de 120 Voltios AC, 30 Amperios Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 20 Amperios, Receptáculo Dobles Tomacorrientes de 12 Voltios DCMientras se Utiliza el Generador Protección Contra Fallos de Conexión a TierraCompruebe el Disyuntor Gfci Control de la Energía No Sobrecargue GeneradorCapacidad EjemploMantenimiento del Motor EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del GeneradorPara Limpiar el Generador AlmacenamientoAlmacenando el Generador Almacenando el MotorNotas Problemo Accion Causa Diagnositicos DE AveríasGarantía Limitada