Briggs & Stratton PRO4000 owner manual Generator Storage, Generator Cleaning

Page 16

BSPP Generator

4.Place screen, retaining ring, and o-ring into fuel valve. Install sediment cup and tighten securely.

5.Move fuel valve to “On” position, and check for leaks. Replace o-ring if there is any leakage.

Generator Storage

Clean the generator as outlined in “Generator Cleaning”.

Check that cooling air slots and openings on generator are open and unobstructed.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than

30 days, use the following guidelines to prepare it for storage.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

Engine Storage

See engine owner’s manual for instructions.

Other Storage Tips

To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor. The unit and fuel can then be stored for up to

24 months. Fuel stabilizer can be purchased locally.

DO NOT store fuel from one season to another unless it has been treated as described above.

Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.

Store unit in a clean and dry area.

16

Image 16
Contents PRO4000 01932 Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Install Wheel KITCarton Contents Remove Generator From CartonWhen Adding Fuel Before Starting the EngineAdd Fuel Add Engine OilUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Stopping the EngineCharging a Battery Cold Weather OperationOperating Automatic Idle Control To recharge 12 Volt batteries, proceed as followsRemove shelter when temperatures are above 40F 4C Permanent Cold Weather ShelterReceptacles 120/240 Volt AC, 20 Amp Locking ReceptacleVolt AC, 20 Amp, Duplex Receptacle Volt DC, 10 Amp ReceptacleTest Gfci Circuit Breaker Ground Fault ProtectionDuring Generator Use Power Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceGenerator Cleaning StorageGenerator Storage Engine Storage Other Storage TipsTroubleshooting Problem Cause CorrectionBspp Generator Consumer Use Years Years or YearSymboles de Danger et Moyens Table DES MatièresDescription DE L Équipement AvertissementLe générateur produit une tension élevée Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLorsque Vous Réglez OU Réparez Votre Générateur Unintentional peut résulter dans feu ou électriqueLors DE Tests Dallumage DU Moteur Connaissez Votre Générateur Arrêteur d’étincellesFaites linstallation comme indiqué ci-après Figure AssemblageEnlever le générateur de la boite Les Contenus De BoîteInstallez le bouchon à essence et essuyez lessence déversée Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Ajoutez de lessenceEmplacement de la Génératrice Utilisation DE LA GénératriceMise à la terre du système Branchement au système électrique dun édificeUtilisation DU Générateur Démarrage du MoteurBranchement des Charges Électriques Arrêt du MoteurFonctionnement PAR Temps Froid Recharge d’une BatterieAbri Permanent Pour Temps Froids VentPrises DE Courant Prise à Verrouillage de 120/240 Volts c.a., 20 AmpèresVolts c.a., 20 Ampères Prise de Courant Double Prise de 10 Ampères, 12 Volts c.cMise à lessai du disjoncteur Gfci Protection contre les fuites de terrePendant le fonctionnement de la génératrice NE PAS Surcharger Générateur CapacitéGestion de la Consommation ExempleRecommandations Générales D’ENTRETIEN SpécificationsEntretien du Moteur Entretien du GénérateurRemisage Nettoyage de GénérateurRemisage du Générateur Remisage du MoteurDépannage Remarques Garantie Limitée Tabla DE Contenidos Descripción DEL EquipoAdvertencia Instrucciones DE SeguridadPeligro Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Montaje Instale EL Juego DE RuedasPara Retirar el Generador de la Caja Contenido de la CajaAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Retire los calzos provisionalesUSO DEL Generador Tierra del SistemaUbicación del Generador Conexión al Sistema Eléctrico de un EdificioOperando EL Generador Precaución Encienda el MotorConexion De Cargas Electricas Parado Del MotorFuncionamiento del Control Automático de Marcha en Vacío Operación Durante UN Clima FríoCarga de la Bateria Figura 35 Refugio Frío Permanente del Tiempo Receptáculos Precaución 120/240 Voltios AC, 20 Amperios, Receptáculo de SeguridadVoltios Juego de Cable de 4 Alambres 240V 120V Neutro CargadoTomacorrientes de 120 Voltios AC, 30 Amperios Volt AC, 20 Amperios, Receptáculo DoblesTomacorrientes de 12 Voltios DC Juego de Cable de 3 AlambresCompruebe el Disyuntor Gfci Protección Contra Fallos de Conexión a TierraMientras se Utiliza el Generador No Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorAlmacenamiento Almacenando el GeneradorPara Limpiar el Generador Almacenando el MotorBspp Generador Problemo Accion Causa Diagnositicos DE AveríasGarantía Limitada
Related manuals
Manual 84 pages 9.15 Kb

PRO4000 specifications

The Briggs & Stratton PRO4000 is a dependable and powerful generator designed to meet the needs of both residential and professional users. With a robust build and advanced technology, it offers an excellent solution for powering essential appliances during outages or for use at worksites.

One of the standout features of the PRO4000 is its impressive peak power output of 4000 watts, providing ample energy for multiple devices. This makes it an ideal choice for running refrigerators, sump pumps, or power tools simultaneously. The generator's continuous running wattage capacity ensures a steady power supply, allowing users to maintain their usual lifestyle even in emergencies.

The PRO4000 is equipped with a reliable Briggs & Stratton engine, renowned in the industry for its durability and efficiency. The engine employs OHV (Overhead Valve) technology, which enhances performance and fuel efficiency while reducing emissions. This means users can operate the generator longer on a single tank of fuel, making it economical and environmentally friendly.

Portability is another significant feature of the PRO4000. It is designed with a compact frame and comes with heavy-duty wheels and a foldable handle. This allows for easy transportation across various terrains, making it suitable for camping trips, construction sites, or any outdoor activities where temporary power is required.

Safety is a priority with the PRO4000. It integrates advanced safety features like overload protection that automatically shuts off the generator to prevent damage, ensuring it runs smoothly and safely. The generator also incorporates a low oil shutdown feature that protects the engine from damage by shutting down when oil levels are too low.

User-friendly controls make the PRO4000 accessible for anyone to operate. The generator features clearly marked outlets for easy connection of devices, and an easy-to-read fuel gauge allows users to monitor fuel levels without opening the tank.

In summary, the Briggs & Stratton PRO4000 stands out with its powerful performance, reliable engine technology, portability, and safety features. Whether for home use during power outages or for commercial applications, the PRO4000 offers the versatility and reliability that users can depend on. It is an investment that ensures peace of mind and preparedness for whatever challenges come your way.