6.04Lock the spacer in place by tightening the locking screw using the supplied allen wrench.
6.05Place the ribbon holder into the cleaver. Push the ribbon holder against the cleaver spacer gauge .
6.06Align the end of the ribbon coating to be within the slot in the cleaver gauge. Adjust the ribbon position by pushing the ribbon holder firmly against the cleaver gauge and pulling back on the ribbon.
Note: Ensure that no fibers are crossed.
6.07 Close the cleaver clamping lid 1 .
6.08 Slide the scoring sled 2 across the bottom of the fibers.
10