3M 2600 manual Cleaver Operation

Page 9

5.03Lay the stripped ribbon between the guide forks. The ribbon should be positioned so that 1" to 2" (25 mm to 51 mm) of unstripped ribbon extends beyond the end of the holder.

5.04 Place the cover over the ribbon and snap into place.

6.0 Cleaver Operation

6.01The Alcoa Fujikura Model CT-03, CT-04, CT-04B, or CT-07, is required for the cleaving process.

Note: Sumitomo Model FC-4 Cleaver may also be used, along with the 2651-A Fiber Viewer.

6.02If present, the guide plate must be removed so that the cleaver spacer gauge assembly can be installed. Remove the screws that secure the guide plate. Remove the guide plate.

6.03Install the cleaver spacer gauge in the slot. The spacer should be snug against the wall near the rubber pad.

9

Image 9
Contents Instructions Page Contents 265 673 Preparation Kit GeneralColor Code Product Number Fiber CountCable Preparation Ribbon PreparationConstruction Color Page Application Color Ribbon Holder PreparationCleaver Operation Page Visual Inspection of the Cleave Fiber Insertion Applying the Pre-load Not Centered Splice ActuationMulti-Fiber Stripper Cleaning and Maintenance Page Helpful Hints Ordering Information Splice Organizer Trays and AccessoriesSplice Preparation Kits System Components/Spare PartsPage Important Notice 3M Telecom Systems Group