3M 2600 manual Fiber Insertion

Page 12

7.03 Defect in cleaved fibers.

7.04If fibers are properly cleaved:

-Remove the fiber viewer from the cleaver, and

-Remove the ribbon holder from the cleaver.

8.0 Fiber Insertion

8.01Move the actuation lever on the actuator tool all the way to the right. Install the magnifying lens and pen light assemblies. Move the preload levers to the up position.

8.02Place a Fibrlok Multi-Fiber Optical Splice into the actuator tool so that the covers open toward the back of the actuator tool. Open both covers completely.

Note: Carefully follow safety, health, and disposal information on splice label or Material Safety Data Sheet.

8.03Lay the back end of the ribbon holder against the backstop of the holder guide track.

8.04Position the magnifying lens assembly and pen light assembly over the splice.

defective

Preload

Preload

Lever

Lever

Actuation Lever

12

Image 12
Contents Instructions Page Contents 265 673 General Preparation KitColor Code Product Number Fiber CountCable Preparation Ribbon PreparationConstruction Color Page Ribbon Holder Preparation Application ColorCleaver Operation Page Visual Inspection of the Cleave Fiber Insertion Applying the Pre-load Splice Actuation Not CenteredMulti-Fiber Stripper Cleaning and Maintenance Page Helpful Hints Splice Organizer Trays and Accessories Ordering InformationSplice Preparation Kits System Components/Spare PartsPage 3M Telecom Systems Group Important Notice