3M 2600 manual Multi-Fiber Stripper Cleaning and Maintenance

Page 15

10.03Remove the cover of each ribbon holder by squeezing the center tabs and lifting the outer tabs.

10.04 Gently lift the splice and ribbons out of the actuator tool.

10.05Turn the splice over and verify that the wedge has been fully pushed against the splice body.

10.06If the wedge is not against the splice body, move the actuation lever to the right, place the splice back into the actuator tool and squeeze the actuation lever again.

10.07 Remove the ribbon holders from the actuator tool.

11.0 Multi-Fiber Stripper Cleaning and Maintenance

11.01Tube Guide

a.The stripper tube guide should be cleaned periodically to ensure good performance. Remove the tube guide by unlatching the tube lock with the white pushout tool. Pull the tube guide out of the pivot housing.

b.Clean the inside of the tube guide with compressed air. A length of unstripped ribbon may also be used for cleaning if

compressed air is not available. Also clean around the

Clean

outside tip of the tube guide.

 

15

Image 15
Contents Instructions Page Contents 265 673 Product Number Fiber Count GeneralPreparation Kit Color CodeCable Preparation Ribbon PreparationConstruction Color Page Application Color Ribbon Holder PreparationCleaver Operation Page Visual Inspection of the Cleave Fiber Insertion Applying the Pre-load Not Centered Splice ActuationMulti-Fiber Stripper Cleaning and Maintenance Page Helpful Hints System Components/Spare Parts Splice Organizer Trays and AccessoriesOrdering Information Splice Preparation KitsPage Important Notice 3M Telecom Systems Group