c.Insert the tube guide into the pivot housing. Secure the tube guide with the tube guide lock.

11.02Stripper Blades - Cleaning

a.If the stripper performance is unsatisfactory after the normal cleaning procedure (section 4.10), the stripper blades may need to be removed from the handle assembly for a more thorough cleaning.

b.Remove the tube guide per section 11.01 a. Use the pushout tool to push the blades out of the handle assembly.

c.Remove all foreign material from the front and back sides of the blades, especially around the semicircular region.

d. Replace the blades in the pivot housing. The molded recesses in the blades should face outward. Push the blades into place with the pushout tool. Reinstall and secure the tube guide per section 11.01 c.

e.After installing blades, tube guide, and tube lock, close the handles once to align the blades.

16

Image 16
Contents Instructions Page Contents 265 673 General Preparation KitColor Code Product Number Fiber CountRibbon Preparation Cable PreparationConstruction Color Page Ribbon Holder Preparation Application ColorCleaver Operation Page Visual Inspection of the Cleave Fiber Insertion Applying the Pre-load Splice Actuation Not CenteredMulti-Fiber Stripper Cleaning and Maintenance Page Helpful Hints Splice Organizer Trays and Accessories Ordering InformationSplice Preparation Kits System Components/Spare PartsPage 3M Telecom Systems Group Important Notice