4.04Connect the power cord from the AC adapter to the stripper handle. Plug the AC adapter into an electrical outlet.

Note: An optional 6 volt battery and cord are available.

4.05Arrange the fibers in the splice tray per tray instructions. Trim the ribbon end so that it extends approximately 3/4" (19 mm) beyond the center of the splice.

4.06Insert the ribbon into the tube guide and position the ribbon so that

1 1/4" to 1 1/2" (32 mm to 38 mm) of coating will be removed.

4.07Close the handle on the stripper. This will activate the heating unit which will soften the coating of the ribbon.

Note: The heating unit becomes hot. Use care when handling.

4.08Heat the coating until it softens (usually 8 to 10 seconds at room temperature). Slowly pull the ribbon straight out of the stripper. The handles should remain closed until the ribbon is completely out of the stripper.

Note: Do not keep the handles closed for more than 25 seconds or the heating unit may become damaged.

Note: Heating time will vary with fiber type and ambient temperature. If difficulty is experienced, refer to Section 12.

7

Image 7
Contents Instructions Page Contents 265 673 Product Number Fiber Count GeneralPreparation Kit Color CodeRibbon Preparation Cable PreparationConstruction Color Page Application Color Ribbon Holder PreparationCleaver Operation Page Visual Inspection of the Cleave Fiber Insertion Applying the Pre-load Not Centered Splice ActuationMulti-Fiber Stripper Cleaning and Maintenance Page Helpful Hints System Components/Spare Parts Splice Organizer Trays and AccessoriesOrdering Information Splice Preparation KitsPage Important Notice 3M Telecom Systems Group