Intel SE7501CW2 manual Installing Chassis Standoffs, Installing the Rubber Bumper

Page 10

Intel Server Board SE7501CW2 Installation and Integration Guide

Installing Chassis Standoffs

If your chassis does not have standoffs placed as shown, you must rearrange them so they match the holes in the server board. Failure to properly rearrange the metal standoffs may cause the server board to malfunction and permanently damage it. Your chassis may be different from the illustration, but you must still arrange the standoffs properly.

When using an Intel Server Chassis SC5200, positions 1, 4, 6, 20, 23, and 26 come preinstalled. You must install standoffs in positions 7, 18, and 19. Install standoffs in the eight positions marked P regardless of whether one or two processors will be installed. Standoffs are included with this chassis.

Installing the Rubber Bumper

Attach the rubber bumper to the chassis. The bumper should cover the indicated chassis standoff hole. On an Intel Server Chassis SC5200, the standoff is marked ‘S’. On other chassis, place the bumper approximately 3 inches (7.6 cm) below and to the left of the standoffs marked P as shown.

Installing the Server Board

1.Place the board into the chassis, making sure that the back panel’s I/O shield and chassis standoffs align correctly.

2.Attach the board with the included screws at the ten locations shown.

Note:

If you are installing only one processor, you must also insert screws into the four standoff locations around the CPU2 socket.

10

Image 10
Contents Server Installation and Integration Guide Revision History Table of Contents Administrator computers Client computers Target Audience Document OverviewThank you Troubleshooting Guide Minimum Hardware RequirementsPrepare for Assembly Hardware IntegrationSafety Instructions and Information Important Safety InformationElectrostatic Discharge ESD About the I/O Shield Chassis Preparation and Server Board InstallationInstalling the I/O Shield Attaching the Gasket to the I/O ShieldInstalling the Rubber Bumper Installing Chassis StandoffsInstalling the Server Board Installing Memory Opening the Socket Lever Installing the Boxed Intel Xeon ProcessorChoosing the Processor Socket Attaching the ProcessorApplying Thermal Grease Installing the Retention MechanismAttaching the Heat Sink and Retention Clips Attaching the Fan/Intake Assembly Installing the Processor Wind TunnelAttaching the Heat Sink Fan Attaching the Wind Tunnel Making Required Connections to the Server Board Making Optional Connections to the Server Board Installing the Serial B Cable IDE or Scsi Cables Installing the Access CoverCable Routing Intel Server Chassis SC5200 Floppy and Front Panel CablesInstalling the Chassis Feet Pedestal Mode Installing into a Rack Rack ModeFinishing Up Updating the Bios Installing the Operating SystemLANDesk* Client Manager Installing LANDesk Client ManagerLANDesk System Requirements Installing the Intel SMaRT Tool Thank you for purchasing Intel products