Chassis Preparation and Server Board Installation

About the I/O Shield

An ATX 2.03-compliant I/O shield is provided with your server board. The shield is required by Electromagnetic Interference (EMI) regulations. It minimizes EMI and helps obtain proper cooling of the server.

The shield fits the rectangular opening near the power supply in the back of the chassis. The shield has cutouts that match the external I/O connectors of the server board (such as the keyboard and mouse connectors).

Attaching the Gasket to the I/O Shield

1.Remove the two backing strips from the gasket.

2.Press the gasket onto the inside face of the I/O shield as shown.

Attaching the Label to the I/O Shield

1.Remove the backing from the label included with your server board.

2.Press the label onto the outside face of the I/O shield (A).

Installing the I/O Shield

Install the I/O shield from inside the chassis, with the label facing outward.

1.Insert one edge, and rotate the I/O shield into the chassis cutout.

2.Press firmly until the I/O shield clicks into place.

9

Image 9
Contents Server Installation and Integration Guide Revision History Table of Contents Administrator computers Client computers Document Overview Target AudienceThank you Minimum Hardware Requirements Troubleshooting GuideHardware Integration Prepare for AssemblyImportant Safety Information Safety Instructions and InformationElectrostatic Discharge ESD Installing the I/O Shield Chassis Preparation and Server Board InstallationAbout the I/O Shield Attaching the Gasket to the I/O ShieldInstalling Chassis Standoffs Installing the Rubber BumperInstalling the Server Board Installing Memory Choosing the Processor Socket Installing the Boxed Intel Xeon ProcessorOpening the Socket Lever Attaching the ProcessorInstalling the Retention Mechanism Applying Thermal GreaseAttaching the Heat Sink and Retention Clips Installing the Processor Wind Tunnel Attaching the Fan/Intake AssemblyAttaching the Heat Sink Fan Attaching the Wind Tunnel Making Required Connections to the Server Board Making Optional Connections to the Server Board Installing the Serial B Cable Cable Routing Intel Server Chassis SC5200 Installing the Access CoverIDE or Scsi Cables Floppy and Front Panel CablesInstalling into a Rack Rack Mode Installing the Chassis Feet Pedestal ModeFinishing Up Installing the Operating System Updating the BiosInstalling LANDesk Client Manager LANDesk* Client ManagerLANDesk System Requirements Installing the Intel SMaRT Tool Thank you for purchasing Intel products