Intel SE7501CW2 manual Installing Memory

Page 11

Intel Server Board SE7501CW2 Installation and Integration Guide

Installing Memory

The server board supports only DDR266- compliant DIMMs. The minimum supported memory configuration is 128 MB, using one 128-MB DIMM. The maximum configurable memory size is 8 GB using 4 2-GB DIMMs.

If a single DIMM is used, you must install it in the DIMM 1A socket. Bank 1 must be fully populated before you install any memory in Bank 2, and Bank 2 only operates with two DIMMs installed. DIMMs must be identical within each bank.

Note:

Use memory that has been tested for compatibility with the server board. For a list of tested memory, see:

http://support.intel.com/support/motherboards/server/SE7501CW2/tested_mem.htm

If the server board is not already installed in the chassis, remove the server board from its packaging and place it on a clean ESD-protected work surface.

1.Open both DIMM socket levers.

2.Insert DIMM, making sure the connector edge of the DIMM aligns correctly with the slot.

3.Check that the socket levers are securely latched. DIMMs must be populated in identical pairs.

11

Image 11
Contents Server Installation and Integration Guide Revision History Table of Contents Administrator computers Client computers Thank you Document OverviewTarget Audience Minimum Hardware Requirements Troubleshooting GuideHardware Integration Prepare for AssemblyElectrostatic Discharge ESD Important Safety InformationSafety Instructions and Information Attaching the Gasket to the I/O Shield Chassis Preparation and Server Board InstallationInstalling the I/O Shield About the I/O ShieldInstalling the Server Board Installing Chassis StandoffsInstalling the Rubber Bumper Installing Memory Attaching the Processor Installing the Boxed Intel Xeon ProcessorChoosing the Processor Socket Opening the Socket LeverAttaching the Heat Sink and Retention Clips Installing the Retention MechanismApplying Thermal Grease Attaching the Heat Sink Fan Installing the Processor Wind TunnelAttaching the Fan/Intake Assembly Attaching the Wind Tunnel Making Required Connections to the Server Board Making Optional Connections to the Server Board Installing the Serial B Cable Floppy and Front Panel Cables Installing the Access CoverCable Routing Intel Server Chassis SC5200 IDE or Scsi CablesInstalling into a Rack Rack Mode Installing the Chassis Feet Pedestal ModeFinishing Up Installing the Operating System Updating the BiosLANDesk System Requirements Installing LANDesk Client ManagerLANDesk* Client Manager Installing the Intel SMaRT Tool Thank you for purchasing Intel products