Intel manual Intel Server Chassis SR1450 User Guide, TP01609

Page 37
TP01609

Hardware Installations and Upgrades

14.Install the chassis cover. For instructions, see “Installing the Chassis Cover.”

15.(Optional) Install the front bezel. For instructions, see “Removing and Installing the Front Bezel.”

16.Plug all peripheral devices and the AC power cable(s) back into the server.

Installing a Floppy Drive into the Converted Hard Drive Bay

The slimline floppy drive conversion kit must be installed in the center hard drive bay.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.”

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”

4.Remove the front bezel if it is installed. For instructions, see “Removing and Installing the Front Bezel.”

5.Remove the center hot-swap hard drive carrier from the chassis.

6.Remove the screws that attach the slide rails to the floppy drive conversion kit carrier.

TP01609

Figure 24. Removing the Rails from the Floppy Drive Conversion Kit Carrier

Intel® Server Chassis SR1450 User Guide

37

Image 37
Contents Order Number: C95452-002 Intel Server Chassis SR1450 User GuideDisclaimer About this Manual PrefaceManual Organization Product Contents, Order Options, and Accessories ƒRiser option, choose one •Full-height PCI-Xriser Additional Information and Software EMC Testing Safety InformationEmissions Disclaimer Intended UsesWarnings Wichtige Sicherheitshinweise Safety Cautions重要安全指导 Consignes de sécurité1 Server Chassis Features Contents2 Hardware Installations and Upgrades Warranty Intel Server Issue Report FormEquipment Log and Worksheets Regulatory and Compliance InformationFigures Tables Figure 1. Intel Server Chassis SR1450 1 Server Chassis FeaturesServer Chassis Features Table 1. Server Chassis FeaturesFeature DescriptionTable 1. Server Chassis Features continued Internal Components Component IdentificationA B C D E F G H I J K Standard Control PanelCallout FunctionAB C D E F Intel Local Control PanelN M L K J I H GFigure 4. Intel Local Control Panel Features Back Panel FeaturesFigure 5. Chassis Back Hard Disk Drives Peripheral Devices Front FeaturesNOTES Floppy / CD-ROM / DVD-ROMSlimline Carriers Advanced Management OptionsIntel Management Module Front Bezels Rack-MountedSystemsBefore You Begin 2 Hardware Installations and UpgradesTools and Supplies Needed System ReferencesRemoving the Chassis Cover Removing and Installing the Chassis CoverFigure 8. Installing the Chassis Cover Installing the Chassis CoverRemoving the Front Bezel Removing and Installing the Front BezelInstalling the Front Bezel Removing and Installing the Processor Air DuctRemoving the Processor Air Duct Installing the Processor Air DuctFigure 13. Removing the Processor Air Duct Figure 14. Preparing the Processor Air Duct Figure 15. Installing the Processor Air DuctTP01597 TP01598Removing a SATA or SCSI Hot-swapHard Disk Drive Installing and Removing a Hard Disk DriveB A B Installing a SATA or SCSI Hot-swapHard Disk DriveIntel Server Chassis SR1450 User Guide TP01603 Installing a Floppy Drive into Slimline BayTP01604 TP01606 Removing a Floppy Drive from the Slimline BayTP01609 TP01323 C AB 5.Remove cables from the interposer board Installing or Removing a CD-ROMor DVD-ROMDrive TP01614 Installing and Removing a PCI Riser Card Installing a PCI Riser Card 10.Release the blue locking lever Removing a PCI Riser Card Installing a PCI Add-inCard Installing and Removing a PCI Add-inCardTP01617 A B D CRemoving a PCI Add-inCard TP01619 Replacing the Standard Control PanelReplacing the Intel Local Control Panel 8.If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using the optional bezel, make sure the back half of the tray is secured in the “shortened” position Replacing System Fans Replacing the Single System PCI Fan 8.Connect the fan into the fan connector Installing the Power Supply Air Duct Removing the Power Supply Air DuctFigure 42. Removing a Power Supply Fan Module Replacing a Power Supply Fan ModuleReplacing the Power Distribution Board 19.Reconnect the power supply fans A B B Removing a Hot-SwapPower Supply Replacing the Hot-SwapPower SupplyInstalling a Hot-SwapPower Supply system or wall outlet Removing the SATA or SCSI Backplane Installing the SATA or SCSI Backplane 8.Connect the following cables to the backplane Cable Routing Technical ReferenceTable 3. SATA Cable Routing Reference A B E C DTechnical Reference TP01612520-WSingle Power Supply Input Voltages Power Supply Specifications520-WSingle Power Supply Output Voltages Table 5. Environmental Specifications System Environmental SpecificationsEquipment Log Equipment Log and WorksheetsDate Installed ItemWorksheet, Calculating DC Power Usage Calculating Power UsageCurrent Usage Voltage level and total current Table 7. Power Usage WorksheetTotal Watts V X A = WRegulatory and Compliance Information Product Safety ComplianceProduct Regulatory Compliance Product EMC Compliance – Class A ComplianceProduct Regulatory Compliance Markings Certifications / Registrations / DeclarationsFCC USA Electromagnetic Compatibility NoticesEurope CE Declaration of Conformity Industry Canada ICES-003English translation of the notice above BSMI Taiwan VCCI JapanKorean RRL Compliance Regulated Specified Components World Wide Web Getting HelpTelephone Board / Chassis Information Intel Server Issue Report FormDate Submitted Company Name Contact Name Email Address Intel Server ProductOperating System Information Operating System Version Service Pack #Peripheral Information Hard Drive InformationComplete Problem Description Page Limited Warranty for Intel Chassis Subassembly WarrantyExtent of Limited Warranty ProductsLimitations of Liability Warranty Limitations and ExclusionsTelephone Support How to Obtain Warranty ServiceReturning a Defective Product