Intel SR1450 manual Removing a PCI Riser Card

Page 46

Hardware Installations and Upgrades

Removing a PCI Riser Card

The PCI riser card can be replaced if it fails or if a different option is required. To replace the PCI riser card, use the following instructions to remove it, and then follow the instructions under “Installing a PCI Riser Card” to install a new riser card.

NOTE

To eliminate the possibility of installing the replacement card on the wrong side of the PCI riser assembly, replace one card at a time.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.”

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”

4.Lift up on the two blue levers to lift the PCI riser assembly from the chassis.

5.Remove any PCI add-in cards that are installed in the connector. For instructions, see “Removing a PCI Add-in Card.”

6.Push back on the blue release lever at the end of the riser card. While holding the lever back, push firmly on the other edge of the board to disengage the riser card from the assembly.

7.Follow the steps under “Installing a PCI Riser Card” to install a replacement riser card.

8.Install the chassis cover. For instructions, see “Installing the Chassis Cover.”

46

Image 46
Contents Intel Server Chassis SR1450 User Guide Order Number: C95452-002Disclaimer About this Manual PrefaceManual Organization Product Contents, Order Options, and Accessories ƒRiser option, choose one •Full-height PCI-Xriser Additional Information and Software Emissions Disclaimer Safety InformationEMC Testing Intended UsesWarnings 重要安全指导 Safety CautionsWichtige Sicherheitshinweise Consignes de sécurité1 Server Chassis Features Contents2 Hardware Installations and Upgrades Equipment Log and Worksheets Intel Server Issue Report FormWarranty Regulatory and Compliance InformationFigures Tables 1 Server Chassis Features Figure 1. Intel Server Chassis SR1450Feature Table 1. Server Chassis FeaturesServer Chassis Features DescriptionTable 1. Server Chassis Features continued Component Identification Internal ComponentsCallout Standard Control PanelA B C D E F G H I J K FunctionN M L K J Intel Local Control PanelAB C D E F I H GFigure 4. Intel Local Control Panel Features Back Panel FeaturesFigure 5. Chassis Back Hard Disk Drives Peripheral Devices Front FeaturesNOTES Floppy / CD-ROM / DVD-ROMSlimline Carriers Advanced Management OptionsIntel Management Module Rack-MountedSystems Front BezelsTools and Supplies Needed 2 Hardware Installations and UpgradesBefore You Begin System ReferencesRemoving and Installing the Chassis Cover Removing the Chassis CoverInstalling the Chassis Cover Figure 8. Installing the Chassis CoverRemoving and Installing the Front Bezel Removing the Front BezelRemoving and Installing the Processor Air Duct Installing the Front BezelRemoving the Processor Air Duct Installing the Processor Air DuctFigure 13. Removing the Processor Air Duct TP01597 Figure 15. Installing the Processor Air DuctFigure 14. Preparing the Processor Air Duct TP01598Installing and Removing a Hard Disk Drive Removing a SATA or SCSI Hot-swapHard Disk DriveInstalling a SATA or SCSI Hot-swapHard Disk Drive B A BIntel Server Chassis SR1450 User Guide Installing a Floppy Drive into Slimline Bay TP01603TP01604 Removing a Floppy Drive from the Slimline Bay TP01606TP01609 TP01323 C AB 5.Remove cables from the interposer board Installing or Removing a CD-ROMor DVD-ROMDrive TP01614 Installing and Removing a PCI Riser Card Installing a PCI Riser Card 10.Release the blue locking lever Removing a PCI Riser Card Installing and Removing a PCI Add-inCard Installing a PCI Add-inCardA B D C TP01617Removing a PCI Add-inCard Replacing the Standard Control Panel TP01619Replacing the Intel Local Control Panel 8.If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using the optional bezel, make sure the back half of the tray is secured in the “shortened” position Replacing System Fans Replacing the Single System PCI Fan 8.Connect the fan into the fan connector Removing the Power Supply Air Duct Installing the Power Supply Air DuctReplacing a Power Supply Fan Module Figure 42. Removing a Power Supply Fan ModuleReplacing the Power Distribution Board 19.Reconnect the power supply fans A B B Replacing the Hot-SwapPower Supply Removing a Hot-SwapPower SupplyInstalling a Hot-SwapPower Supply system or wall outlet Removing the SATA or SCSI Backplane Installing the SATA or SCSI Backplane 8.Connect the following cables to the backplane Technical Reference Cable RoutingTechnical Reference A B E C DTable 3. SATA Cable Routing Reference TP01612520-WSingle Power Supply Input Voltages Power Supply Specifications520-WSingle Power Supply Output Voltages System Environmental Specifications Table 5. Environmental SpecificationsDate Installed Equipment Log and WorksheetsEquipment Log ItemWorksheet, Calculating DC Power Usage Calculating Power UsageCurrent Usage Total Watts Table 7. Power Usage WorksheetVoltage level and total current V X A = WProduct Regulatory Compliance Product Safety ComplianceRegulatory and Compliance Information Product EMC Compliance – Class A ComplianceCertifications / Registrations / Declarations Product Regulatory Compliance MarkingsElectromagnetic Compatibility Notices FCC USAEurope CE Declaration of Conformity Industry Canada ICES-003English translation of the notice above BSMI Taiwan VCCI JapanKorean RRL Compliance Regulated Specified Components World Wide Web Getting HelpTelephone Date Submitted Company Name Contact Name Intel Server Issue Report FormBoard / Chassis Information Email Address Intel Server ProductPeripheral Information Operating System Version Service Pack #Operating System Information Hard Drive InformationComplete Problem Description Page Extent of Limited Warranty WarrantyLimited Warranty for Intel Chassis Subassembly ProductsWarranty Limitations and Exclusions Limitations of LiabilityTelephone Support How to Obtain Warranty ServiceReturning a Defective Product