Intel SR1450 manual Product Contents, Order Options, and Accessories

Page 4

Preface

Product Contents, Order Options, and Accessories

The server chassis SR1450 is compatible with the Intel® Server Board SE7520JR2.

Your Server Chassis SR1450 ships with the following items:

ƒA box of hardware components, referred to below as the “hardware box”

ƒOne 520W power supply module, installed in the chassis

ƒPower distribution board, installed in the chassis

ƒLow-profile PCI-X riser, installed in the chassis

ƒCD-ROM / DVD drive tray, installed in the chassis

ƒSystem fan module, installed in the chassis

ƒSingle system fan, installed in the chassis

ƒTwo power supply fan modules, installed in the chassis

ƒChassis intrusion switch, installed in the chassis

ƒPower supply air duct, installed in the chassis

ƒProcessor air duct, installed in the chassis

ƒCD-ROM filler panel, installed in the chassis

ƒFloppy carrier assembly, in the hardware box

ƒCables, in the hardware box

ƒSix 32-6mm flat screws for installing drive component, in the hardware box

ƒSeven screws for mounting the server board into the chassis, in the hardware box

ƒIntel® Server Chassis SR1450 Quick Start User’s Guide , in the chassis box

ƒAttention document, in the chassis box

iv

Image 4
Contents Intel Server Chassis SR1450 User Guide Order Number: C95452-002Disclaimer About this Manual PrefaceManual Organization Product Contents, Order Options, and Accessories ƒRiser option, choose one •Full-height PCI-Xriser Additional Information and Software Safety Information EMC TestingEmissions Disclaimer Intended UsesWarnings Safety Cautions Wichtige Sicherheitshinweise重要安全指导 Consignes de sécurité1 Server Chassis Features Contents2 Hardware Installations and Upgrades Intel Server Issue Report Form WarrantyEquipment Log and Worksheets Regulatory and Compliance InformationFigures Tables 1 Server Chassis Features Figure 1. Intel Server Chassis SR1450Table 1. Server Chassis Features Server Chassis FeaturesFeature DescriptionTable 1. Server Chassis Features continued Component Identification Internal ComponentsStandard Control Panel A B C D E F G H I J KCallout FunctionIntel Local Control Panel AB C D E FN M L K J I H GFigure 4. Intel Local Control Panel Features Back Panel FeaturesFigure 5. Chassis Back Hard Disk Drives Peripheral Devices Front FeaturesNOTES Floppy / CD-ROM / DVD-ROMSlimline Carriers Advanced Management OptionsIntel Management Module Rack-MountedSystems Front Bezels2 Hardware Installations and Upgrades Before You BeginTools and Supplies Needed System ReferencesRemoving and Installing the Chassis Cover Removing the Chassis CoverInstalling the Chassis Cover Figure 8. Installing the Chassis CoverRemoving and Installing the Front Bezel Removing the Front BezelRemoving and Installing the Processor Air Duct Installing the Front BezelRemoving the Processor Air Duct Installing the Processor Air DuctFigure 13. Removing the Processor Air Duct Figure 15. Installing the Processor Air Duct Figure 14. Preparing the Processor Air DuctTP01597 TP01598Installing and Removing a Hard Disk Drive Removing a SATA or SCSI Hot-swapHard Disk DriveInstalling a SATA or SCSI Hot-swapHard Disk Drive B A BIntel Server Chassis SR1450 User Guide Installing a Floppy Drive into Slimline Bay TP01603TP01604 Removing a Floppy Drive from the Slimline Bay TP01606TP01609 TP01323 C AB 5.Remove cables from the interposer board Installing or Removing a CD-ROMor DVD-ROMDrive TP01614 Installing and Removing a PCI Riser Card Installing a PCI Riser Card 10.Release the blue locking lever Removing a PCI Riser Card Installing and Removing a PCI Add-inCard Installing a PCI Add-inCardA B D C TP01617Removing a PCI Add-inCard Replacing the Standard Control Panel TP01619Replacing the Intel Local Control Panel 8.If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using the optional bezel, make sure the back half of the tray is secured in the “shortened” position Replacing System Fans Replacing the Single System PCI Fan 8.Connect the fan into the fan connector Removing the Power Supply Air Duct Installing the Power Supply Air DuctReplacing a Power Supply Fan Module Figure 42. Removing a Power Supply Fan ModuleReplacing the Power Distribution Board 19.Reconnect the power supply fans A B B Replacing the Hot-SwapPower Supply Removing a Hot-SwapPower SupplyInstalling a Hot-SwapPower Supply system or wall outlet Removing the SATA or SCSI Backplane Installing the SATA or SCSI Backplane 8.Connect the following cables to the backplane Technical Reference Cable RoutingA B E C D Table 3. SATA Cable Routing ReferenceTechnical Reference TP01612520-WSingle Power Supply Input Voltages Power Supply Specifications520-WSingle Power Supply Output Voltages System Environmental Specifications Table 5. Environmental SpecificationsEquipment Log and Worksheets Equipment LogDate Installed ItemWorksheet, Calculating DC Power Usage Calculating Power UsageCurrent Usage Table 7. Power Usage Worksheet Voltage level and total currentTotal Watts V X A = WProduct Safety Compliance Regulatory and Compliance InformationProduct Regulatory Compliance Product EMC Compliance – Class A ComplianceCertifications / Registrations / Declarations Product Regulatory Compliance MarkingsElectromagnetic Compatibility Notices FCC USAEurope CE Declaration of Conformity Industry Canada ICES-003English translation of the notice above BSMI Taiwan VCCI JapanKorean RRL Compliance Regulated Specified Components World Wide Web Getting HelpTelephone Intel Server Issue Report Form Board / Chassis InformationDate Submitted Company Name Contact Name Email Address Intel Server ProductOperating System Version Service Pack # Operating System InformationPeripheral Information Hard Drive InformationComplete Problem Description Page Warranty Limited Warranty for Intel Chassis SubassemblyExtent of Limited Warranty ProductsWarranty Limitations and Exclusions Limitations of LiabilityTelephone Support How to Obtain Warranty ServiceReturning a Defective Product