Hardware Installations and Upgrades
Removing a PCI Add-in Card
1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.”
2.Power down the server and unplug all peripheral devices and the AC power cable(s).
3.Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”
4.Pull up on the two latches on the riser assembly.
5.Lift the PCI riser assembly from the chassis.
6.Open the PCI retention clip on the PCI riser card assembly.
7.Remove the
8.Replace the filler panel at the back of the riser assembly.
9.Close the retention clip.
10.Position the riser assembly over the PCI sockets on the server board.
11.Push the riser assembly down until the assembly is securely seated.
12.Install the chassis cover. For instructions, see “Installing the Chassis Cover.”
13.Plug all peripheral devices and the AC power cable(s) back into the server.
Intel® Server Chassis SR1450 User Guide | 49 |