Intel SR1450 manual system or wall outlet

Page 63
Manual background

Hardware Installations and Upgrades

Removing and Installing the SATA or SCSI Backplane

Your server chassis must be configured with one of the following drive installation options:

ƒA hot-swap SCSI option that came with a SCSI backplane board.

ƒA hot-swap SATA option that came with a SATA backplane board.

CAUTION

The backplane is tool-less, but NOT hot swappable. Before removing or replacing the backplane, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the

system or wall outlet.

The backplane board and the hardware that came with the backplane can be replaced if your backplane fails or if a different option is required. To replace the backplane, use the following instructions to remove and then to install a backplane.

Intel® Server Chassis SR1450 User Guide

63

Image 63
Contents Order Number: C95452-002 Intel Server Chassis SR1450 User GuideDisclaimer Preface About this ManualManual Organization Product Contents, Order Options, and Accessories ƒRiser option, choose one •Full-height PCI-Xriser Additional Information and Software Intended Uses Safety InformationEMC Testing Emissions DisclaimerWarnings Consignes de sécurité Safety CautionsWichtige Sicherheitshinweise 重要安全指导Contents 1 Server Chassis Features2 Hardware Installations and Upgrades Regulatory and Compliance Information Intel Server Issue Report FormWarranty Equipment Log and WorksheetsFigures Tables Figure 1. Intel Server Chassis SR1450 1 Server Chassis FeaturesDescription Table 1. Server Chassis FeaturesServer Chassis Features FeatureTable 1. Server Chassis Features continued Internal Components Component IdentificationFunction Standard Control PanelA B C D E F G H I J K CalloutI H G Intel Local Control PanelAB C D E F N M L K JBack Panel Features Figure 4. Intel Local Control Panel FeaturesFigure 5. Chassis Back Peripheral Devices Front Features Hard Disk DrivesNOTES Advanced Management Options Floppy / CD-ROM / DVD-ROMSlimline CarriersIntel Management Module Front Bezels Rack-MountedSystemsSystem References 2 Hardware Installations and UpgradesBefore You Begin Tools and Supplies NeededRemoving the Chassis Cover Removing and Installing the Chassis CoverFigure 8. Installing the Chassis Cover Installing the Chassis CoverRemoving the Front Bezel Removing and Installing the Front BezelInstalling the Front Bezel Removing and Installing the Processor Air DuctInstalling the Processor Air Duct Removing the Processor Air DuctFigure 13. Removing the Processor Air Duct TP01598 Figure 15. Installing the Processor Air DuctFigure 14. Preparing the Processor Air Duct TP01597Removing a SATA or SCSI Hot-swapHard Disk Drive Installing and Removing a Hard Disk DriveB A B Installing a SATA or SCSI Hot-swapHard Disk DriveIntel Server Chassis SR1450 User Guide TP01603 Installing a Floppy Drive into Slimline BayTP01604 TP01606 Removing a Floppy Drive from the Slimline BayTP01609 TP01323 C AB 5.Remove cables from the interposer board Installing or Removing a CD-ROMor DVD-ROMDrive TP01614 Installing and Removing a PCI Riser Card Installing a PCI Riser Card 10.Release the blue locking lever Removing a PCI Riser Card Installing a PCI Add-inCard Installing and Removing a PCI Add-inCardTP01617 A B D CRemoving a PCI Add-inCard TP01619 Replacing the Standard Control PanelReplacing the Intel Local Control Panel 8.If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using the optional bezel, make sure the back half of the tray is secured in the “shortened” position Replacing System Fans Replacing the Single System PCI Fan 8.Connect the fan into the fan connector Installing the Power Supply Air Duct Removing the Power Supply Air DuctFigure 42. Removing a Power Supply Fan Module Replacing a Power Supply Fan ModuleReplacing the Power Distribution Board 19.Reconnect the power supply fans A B B Removing a Hot-SwapPower Supply Replacing the Hot-SwapPower SupplyInstalling a Hot-SwapPower Supply system or wall outlet Removing the SATA or SCSI Backplane Installing the SATA or SCSI Backplane 8.Connect the following cables to the backplane Cable Routing Technical ReferenceTP01612 A B E C DTable 3. SATA Cable Routing Reference Technical ReferencePower Supply Specifications 520-WSingle Power Supply Input Voltages520-WSingle Power Supply Output Voltages Table 5. Environmental Specifications System Environmental SpecificationsItem Equipment Log and WorksheetsEquipment Log Date InstalledCalculating Power Usage Worksheet, Calculating DC Power UsageCurrent Usage V X A = W Table 7. Power Usage WorksheetVoltage level and total current Total WattsProduct EMC Compliance – Class A Compliance Product Safety ComplianceRegulatory and Compliance Information Product Regulatory ComplianceProduct Regulatory Compliance Markings Certifications / Registrations / DeclarationsFCC USA Electromagnetic Compatibility NoticesIndustry Canada ICES-003 Europe CE Declaration of ConformityEnglish translation of the notice above VCCI Japan BSMI TaiwanKorean RRL Compliance Regulated Specified Components Getting Help World Wide WebTelephone Email Address Intel Server Product Intel Server Issue Report FormBoard / Chassis Information Date Submitted Company Name Contact NameHard Drive Information Operating System Version Service Pack #Operating System Information Peripheral InformationComplete Problem Description Page Products WarrantyLimited Warranty for Intel Chassis Subassembly Extent of Limited WarrantyLimitations of Liability Warranty Limitations and ExclusionsHow to Obtain Warranty Service Telephone SupportReturning a Defective Product