Intel SR1450 manual Replacing the Single System PCI Fan

Page 54
Replacing the Single System PCI Fan

Hardware Installations and Upgrades

8.Note the position of the raised arrows in the top of the replacement fan. Position the fan so one arrow points to the left, and the other arrow points to the rear of the chassis. The fan cable should be pointing to the rear of the chassis.

9.With the fan arrows oriented correctly, insert the replacement fan into the fan module.

10.Connect the power cable for the fan into the fan distribution board.

11.Install the processor air duct. For instructions, see “Installing the Processor Air Duct.”

12.Install the chassis cover. For instructions, see “Installing the Chassis Cover.”

13.Plug all peripheral devices and the AC power cable(s) back into the server.

Replacing the Single System PCI Fan

The single system fan in the Server Chassis SR1450 can be replaced if it fails. Use the steps below to replace the single rotor fan.

CAUTION

The single system PCI fan is NOT hot swappable. Before removing or replacing the system PCI fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord(s) from the system or wall outlet.

1.Observe the safety and ESD precautions at the beginning of this book. See “Safety Information.”

2.Power down the server and unplug all peripheral devices and the AC power cable(s).

3.Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”

4.Disconnect the cable from the fan connector. See letter “A” in “Figure 40. Removing the Single System PCI Fan.”

5.There are no screws or connections to loosen. Lift the failed fan from the fan module assembly. See letter “B” in “Figure 40. Removing the Single System PCI Fan.”

54

Image 54
Contents Intel Server Chassis SR1450 User Guide Order Number: C95452-002Disclaimer Preface About this ManualManual Organization Product Contents, Order Options, and Accessories ƒRiser option, choose one •Full-height PCI-Xriser Additional Information and Software Emissions Disclaimer Safety InformationEMC Testing Intended UsesWarnings 重要安全指导 Safety CautionsWichtige Sicherheitshinweise Consignes de sécuritéContents 1 Server Chassis Features2 Hardware Installations and Upgrades Equipment Log and Worksheets Intel Server Issue Report FormWarranty Regulatory and Compliance InformationFigures Tables 1 Server Chassis Features Figure 1. Intel Server Chassis SR1450Feature Table 1. Server Chassis FeaturesServer Chassis Features DescriptionTable 1. Server Chassis Features continued Component Identification Internal ComponentsCallout Standard Control PanelA B C D E F G H I J K FunctionN M L K J Intel Local Control PanelAB C D E F I H GBack Panel Features Figure 4. Intel Local Control Panel FeaturesFigure 5. Chassis Back Peripheral Devices Front Features Hard Disk DrivesNOTES Advanced Management Options Floppy / CD-ROM / DVD-ROMSlimline CarriersIntel Management Module Rack-MountedSystems Front BezelsTools and Supplies Needed 2 Hardware Installations and UpgradesBefore You Begin System ReferencesRemoving and Installing the Chassis Cover Removing the Chassis CoverInstalling the Chassis Cover Figure 8. Installing the Chassis CoverRemoving and Installing the Front Bezel Removing the Front BezelRemoving and Installing the Processor Air Duct Installing the Front BezelInstalling the Processor Air Duct Removing the Processor Air DuctFigure 13. Removing the Processor Air Duct TP01597 Figure 15. Installing the Processor Air DuctFigure 14. Preparing the Processor Air Duct TP01598Installing and Removing a Hard Disk Drive Removing a SATA or SCSI Hot-swapHard Disk DriveInstalling a SATA or SCSI Hot-swapHard Disk Drive B A BIntel Server Chassis SR1450 User Guide Installing a Floppy Drive into Slimline Bay TP01603TP01604 Removing a Floppy Drive from the Slimline Bay TP01606TP01609 TP01323 C AB 5.Remove cables from the interposer board Installing or Removing a CD-ROMor DVD-ROMDrive TP01614 Installing and Removing a PCI Riser Card Installing a PCI Riser Card 10.Release the blue locking lever Removing a PCI Riser Card Installing and Removing a PCI Add-inCard Installing a PCI Add-inCardA B D C TP01617Removing a PCI Add-inCard Replacing the Standard Control Panel TP01619Replacing the Intel Local Control Panel 8.If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement control panel. If you are not using the optional bezel, make sure the back half of the tray is secured in the “shortened” position Replacing System Fans Replacing the Single System PCI Fan 8.Connect the fan into the fan connector Removing the Power Supply Air Duct Installing the Power Supply Air DuctReplacing a Power Supply Fan Module Figure 42. Removing a Power Supply Fan ModuleReplacing the Power Distribution Board 19.Reconnect the power supply fans A B B Replacing the Hot-SwapPower Supply Removing a Hot-SwapPower SupplyInstalling a Hot-SwapPower Supply system or wall outlet Removing the SATA or SCSI Backplane Installing the SATA or SCSI Backplane 8.Connect the following cables to the backplane Technical Reference Cable RoutingTechnical Reference A B E C DTable 3. SATA Cable Routing Reference TP01612Power Supply Specifications 520-WSingle Power Supply Input Voltages520-WSingle Power Supply Output Voltages System Environmental Specifications Table 5. Environmental SpecificationsDate Installed Equipment Log and WorksheetsEquipment Log ItemCalculating Power Usage Worksheet, Calculating DC Power UsageCurrent Usage Total Watts Table 7. Power Usage WorksheetVoltage level and total current V X A = WProduct Regulatory Compliance Product Safety ComplianceRegulatory and Compliance Information Product EMC Compliance – Class A ComplianceCertifications / Registrations / Declarations Product Regulatory Compliance MarkingsElectromagnetic Compatibility Notices FCC USAIndustry Canada ICES-003 Europe CE Declaration of ConformityEnglish translation of the notice above VCCI Japan BSMI TaiwanKorean RRL Compliance Regulated Specified Components Getting Help World Wide WebTelephone Date Submitted Company Name Contact Name Intel Server Issue Report FormBoard / Chassis Information Email Address Intel Server ProductPeripheral Information Operating System Version Service Pack #Operating System Information Hard Drive InformationComplete Problem Description Page Extent of Limited Warranty WarrantyLimited Warranty for Intel Chassis Subassembly ProductsWarranty Limitations and Exclusions Limitations of LiabilityHow to Obtain Warranty Service Telephone SupportReturning a Defective Product