Transport Timeout allows you to set a transport timeout value. This value is the amount of time the scanner will wait after the last document enters the transport before the transport timeout action is taken. You can specify a time delay setting from 5 to 300 seconds. The default is 10 seconds. If this option is disabled, the transport will continue to run until the Stop/Pause key is pressed or is stopped by the host.
Transport Timeout Action allows you to specify the action that will be taken when the transport timeout has been reached.
•Stop Feeder: stops the feeder and the transport but leaves the scanner enabled. Scanning may be resumed by pressing the Start/Resume button.
•End Job: stops the feeder and the transport and disables the scanner. Scanning cannot be resumed until the scanner is enabled from the host.
Automatically Start Transport if selected, the transport and feeder will automatically start when the scanner is enabled from the host without pressing the Start/Resume button.
Lamp Timeout this value is the amount of time (in minutes) the scanner will wait after the last document enters the transport before the lamps will turn off. You can specify a time delay setting from 1 to 30 minutes. The default is 10 minutes. Using this option extends lamp life and reduces energy consumption. If this option is disabled, the lamps will remain on until the power is turned off.
|