Counter
•Initial Value: this value is used to assign the document count for the next document entering the transport. This value is incremented sequentially by the scanner unless another document count is received from the host. This value is returned in the image header.
•Field Width: used to control the width of the document counter. Values range from 1 to 9.
•Format the format in which the image address appears when printed is defined on the Image Address dialog box. The printed image address may appear in one of three formats:
–Display leading zeros format (e.g., 004.003.002.001)
–Suppress leading zeros format (e.g., 004. 3. 2. 1)
–Compress leading zeros format (e.g., 004.3.2.1)
NOTE: The format chosen does not effect the fixed field of the image address; it is always displayed and printed in its entirety. In the example above, 004 has been defined as a fixed field.
|