Figure 5.2 Output Current Measurement

A series terminating resistor (or series inductor or clamp diode) must be added as shown if the average value of the peak current exceeds 110% of the normal output current.

When choosing Rs, ensure it can withstand the full output voltage across it as well as the power dissipation caused by discharging Co (see Table 5.1) and Cc (20pF/ft) (65.62 pf/m) each cycle as well as conducting the normal output current. It's power dissipation can be

calculated as Pd = (IO 2 R S ) + 1/2(C O

+ C C ) V 2 (REP RATE) .

 

 

 

 

Output Voltage

Co

 

 

 

 

 

1-2.8kV

 

60nF

 

 

 

 

 

3kV-6kV

 

15nF

 

 

 

 

 

10-30kV

 

460pF

 

 

 

 

 

40kV

 

230pF

 

 

 

 

 

Table 5.1

Output Capacitance

   

The 500A/102A/152A/202A power supplies are designed for simple parallel operation. The input power and HV output should be connected directly together. The REMOTE connectors on the input panel can also be connected directly together using a "daisy chain" ribbon cable from the system controller. Each of the power supplies operate at the same time with the total charge rate equal to the sum of each.

Sometimes when operating several units in parallel, the high total power generates noise which interferes with the power supply control. This is usually due to the many interconnecting control cables acting as an antenna picking up noise. The problem usually appears as one or more of the power supplies shuts down when the output voltage increases beyond a certain level. Dressing the control cables as short as possible and close to ground or using shielded cables should help. In severe cases, it is necessary to wrap the cables several times through high permeability ferrite cores at the input panel of each unit.

The 500A/102A/152A/202A power supplies can also be used as an Isolated High Voltage continuous DC power source by adding an external filter capacitor. The value of the filter capacitor depends upon the value of the allowable output voltage ripple value. For parallel operation into DC loads, please contact EMI Customer Service Department. (See Section 5.6).

83-493-001 Revision G

5 - 2

Applications

Image 21
Contents    Installation SpecificationsIntroduction ESDApplications Maintenance and Calibration            #            !          #           Specifications Specifications Specifications Specifications           $         % Input AC Power Connection NON-PFC Version           Output Ground Connection Grounding of Input Line          Eample Of Interface Connection Revision G Operations   &    Fault                Output Current Measurement                       Long Charge Time Operation Revision G Applications !