Jameco Electronics Superpro Series Auto Increment model dependant, Click Option Auto Increment

Page 23

Option: Check Insertion Test if you want the programmer to do an insertion test before any operation on the device. Check Beeper if you want the programmer to beep after any operation. .

Initialize Programmer: Clicking on communication will search the programmer through all possible parallel port. If it finds the programmer, the communication will be successful. If not, Error message will appear.

Data Buffer Clear: If checked, buffer will be cleared each time IC is changed or when loading new data from disk. Normally, this should be checked. For multiple file load, it should be unchecked.

2.5.2Auto Increment (model dependant)

The function allows serial number or signature to be embedded into EPROM or MCU devices automatically.

The selection brings up the Auto Increment set dialogue box. You can set Auto start and Auto end addresses in the buffer, you can also set increment value with any number less than 10. The increment format allows increment as Binary, ASCII HEX and ASCII Decimal. If you want to change the current increment data, open the data edit window and enter data.

For example, suppose you want to program 64 ea chips with IDs of from XT00 to X63 at end of EPROM locations of 87C51. 4 bytes of decimal format is selected.

a)Click Option > Auto Increment

b)Set Start to FFC and End to FFF

c)Set IncValue to 1

d)Set Format to ASCII Decimal

e)Check out Enable Auto Increment

f)Go into Buffer Edit screen at ASCII zone. Change buffer as follows:

FFC : X FFD: T

FFE: 0

FFF: 0

Image 23
Contents Page User’s Guide Copyrights Contents Option Alt-O Customer Support Error MessagesAppendices Test Alt-TFollowing conventions are used in this manual Software include the following featuresProgramming hardware include the following items Guide consists of three main partsStandard package contains the following Minimum requirement is as followsRunning the Program Chips with more than 48 pins on SuperproIII Adapters with 48 pins or less on SuperproIIILoad Ctrl-O File Alt-FEdit Buffer Alt-BSave ExitSwap CopyEncryption Table RadixSearch Next1 Run Device Alt-DRead Run ProgramAuto VerifyBlank Check Data CompareEditAuto Chip EndBuff Start Buff EndWord Format Odd Word ByteEven Word New Pattern Test Alt-TDelete Pattern Edit PatternAuto Find Device SettingOptions Alt-O 4 TTL&CMOS testClick Option Auto Increment Auto Increment model dependantCustomer Support Load config fileSave config file Xeltek Technical Support Limited Warranty Error MessagesInvalid File Type