Jameco Electronics Superpro Series manual File Alt-F, Load Ctrl-O

Page 10

selection of the device to read from. Click on Run from the main screen, which will pop up the Function screen. Click on the Read function, which copies the data from the master chip into the buffer. At this point you may go to the buffer and examine the data to see if it is loaded correctly. The data may be saved to a disk for later use.

Program device: Insert blank chip into the socket and enter on Program function. Device should begin programming at this time followed by verification. Unless the device is new out of box it may be advisable to check for blank before programming.

9.3.2 Error Messages

For any programming error, please refer to the Error Messages section in the Appendix.

2. Description of Menus

2.1File: <Alt-F>

The menu deals with data file management and system interface.

2.1.1Load <Ctrl-O>

Files are loaded into one of two buffer types, HEX/ASCII buffer for EPROMs and Microcontrollers (MCU) and Logic buffer for PLD/PALs, which requires .JED type file.

For EPROMs and MCUs, data types supported are Binary (also .POF), Intel HEX (also extended HEX), Motorola S record, and Tektronix HEX types. Select the appropriate type for the data file.

To select a data file to be loaded, the path and the file name should be entered into the name field. If the full path or the exact name of the file is unknown, then a partial path may be entered using wild cards, e.g. ‘*.*’ or ‘*.BIN’.

Some files have non-zero file start or file offset address. This should be entered in the file start address for proper data loading. Incorrect file offset address will cause FFs to be stored in the beginning part of the buffer. Incorrect large offset address may cause data overflow in the buffer and system failure.

For PLD/PAL devices the Load JED File dialogue box will pop up to enter the file name.

Image 10
Contents Page User’s Guide Copyrights Contents Test Alt-T Customer Support Error MessagesAppendices Option Alt-OGuide consists of three main parts Software include the following featuresProgramming hardware include the following items Following conventions are used in this manualMinimum requirement is as follows Standard package contains the followingRunning the Program Adapters with 48 pins or less on SuperproIII Chips with more than 48 pins on SuperproIIIFile Alt-F Load Ctrl-OExit Buffer Alt-BSave EditCopy SwapNext RadixSearch Encryption TableDevice Alt-D 1 RunRun Program ReadData Compare VerifyBlank Check AutoBuff End Chip EndBuff Start EditAutoWord Format Even Word ByteOdd Word Test Alt-T New PatternEdit Pattern Delete Pattern4 TTL&CMOS test SettingOptions Alt-O Auto Find DeviceAuto Increment model dependant Click Option Auto IncrementSave config file Load config fileCustomer Support Xeltek Technical Support Error Messages Limited WarrantyInvalid File Type