Specifications

9.0SPECIFICATIONS

General & Environmental

Rating

 

 

 

 

 

 

 

 

 

 

 

 

kVA

Models NMB1x and NMB4x = 18

 

 

 

 

 

 

 

 

 

Unit Rating

Models NMB5x and NMB8x = 20

 

 

 

 

 

 

 

 

 

 

 

Amps

Models NMB1x and NMB4x = 100 max

 

 

 

 

 

 

 

 

 

 

 

 

Models NMB5x and NMB8x = 125 max

 

 

 

 

 

 

 

 

 

Safety Standards

 

 

 

UL 1778, c-UL

 

 

 

 

 

 

 

 

 

 

Mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

 

 

 

9.5 (241)

 

 

 

 

 

 

 

 

 

 

 

Depth

In (mm)

 

 

26.5 (700)

 

 

Dimensions

 

 

 

 

 

 

 

Height

 

 

 

30.4 (775)

 

 

 

 

 

 

 

 

 

 

Weight

lb (kg)

287 (130)

 

 

85 (39)

 

transformer model

 

transformerless model

 

 

 

 

Environmental

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Temperature (max)

F (C)

 

32º - 104º (0º - 40º)

 

 

 

 

 

 

 

Relative Humidity

%

 

0-95% non-condensing

 

 

 

 

 

 

 

 

Maximum Operating Altitude

Ft (M)

 

 

10,000 (3000)

 

 

 

 

 

 

 

 

 

 

 

Input Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Input Voltage

VAC

 

 

 

208 or 240

 

 

 

 

 

 

 

 

Input Frequency (nominal)

Hz

 

 

60

 

 

 

 

 

 

 

 

 

Input Frequency Range

Hz

 

 

55-65

 

 

 

 

 

 

 

 

 

 

 

Output Data

 

 

208/240

 

 

240

 

208

 

 

 

 

 

 

 

Output Voltage

VAC

120/120/208/240

 

120/120/240*

 

120/120/208*

 

 

 

 

 

 

 

Transfer Time

msec

 

<4 msec typical

 

 

 

 

 

 

 

 

Output Frequency

Hz

 

 

60

 

 

 

 

 

 

 

 

 

 

 

* Transformerless model requires neutral input

24

Image 28
Contents GXT 10KVA Page Table of Contents Maintenance SpecificationsImportant Safety Instructions Glossary of Symbols System Description General DescriptionFront view Rear view without transformer Rear view with transformer Bypass Mode UPS ModeModes of Operation User Selectable Output Distribution Bypass SwitchMajor Components Required Setup Equipment InspectionEnvironment Site PreparationUnloading the Maintenance Bypass Cabinet UnloadingStationary Mounting Wiring Preparation Preparing Internal WiringDual Source Configuration Cable InstallationMaintenance Bypass Cabinet with transformer Removing the Cover Plates Power Cable InstallationRepo Connection Input and Output Wiring ConduitElectrical connections-transformer model MBC Electrical connections-non-transformer model MBC Connecting Nfinity to Maintenance Bypass with transformer Connecting Nfinity to Maintenance Bypass without transformer GXT10000T-208X GXT10000T-240X Shutting Down the UPS Start-Up and InitializationOperation Maintenance Scheduled MaintenanceProper Care Specifications General & Environmental RatingSpecifications Specifications Page Company Behind the Products Technical Support/ServiceLocations