Fujitsu MB91460 SERIES manual Switch Setting Description, Power Switch, Jumper Setting Description

Page 22

SK-91F467-FLEXRAY V1.1

Jumpers and Switches

3.4Power Supply

There are four on-board switching regulators to provide the voltages 5V, 3.3V, 2.5V and 1.8V on the starter-kit. With the power ON/OFF-switch S8 or S9 (S9 is a soldering option to use a different switch), the main input voltage from DC-connector X5 will be connected to the VIN voltage of the board. The VIN voltage supplies the switching regulators and the VBat voltage of the FlexRay physical layer driver modules from TZM (FT1080), if they are connected to X3 and X7.

 

Switch

 

Setting

 

 

Description

 

S8 or S9

 

ON (1-2)

 

 

Power ON

 

 

OFF (2-3)

 

 

Power OFF

 

 

 

 

 

 

 

 

Default:

 

 

 

 

 

 

 

 

grey

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3-4: Power Switch

With JP91 the pins B14, B15 and B16 of the external bus interface connector X14 can be connected to the VIN voltage, so that it is possible to supply the board from an external connected board e.g. the Fujitsu FlexRay FPGA board.

There is a triple supply monitor on-board, which monitors three of the four DC output voltages and generates a system reset, in case with wrong levels of the on board voltages. 5V and 3.3V are always monitored and the third monitored voltage can be selected with the solder jumpers JP42 and JP43.

With JP68 it is possible to select the whole board supply voltage Vcc to 5V or 3.3V

 

Jumper

 

Setting

 

Description

 

 

JP91

 

ON (closed)

 

 

Vin connected to X14 pins B14, B15 and B16

 

 

 

OFF (open)

 

Vin not connected to X14 pins B14, B15 and B16

 

 

 

 

 

 

 

JP42

 

ON (closed)

 

Vcc1V8 connected to supply monitor

 

 

 

OFF (open)

 

Vcc1V8 not connected to supply monitor

 

 

 

 

 

 

 

JP43

 

ON (closed)

 

Vcc2V5 connected to supply monitor

 

 

 

OFF (open)

 

Vcc2V5 not connected to supply monitor

 

 

 

 

 

 

 

JP68

1-2

 

 

Vcc is connected to 5V

 

 

2-3

 

 

Vcc is connected to 3.3V

 

 

 

 

 

 

Default: grey

Table 3-5: Power supply configurations

FMEMCU-UG-910017-11

- 22 -

© Fujitsu Microelectronics Europe GmbH

Image 22
Contents MB88121 Series MB91460 Series Date Issue Revision HistoryWarranty and Disclaimer No Liability for Consequential DamagesContents Connectors Trouble Shooting SILK-PLOT of the Board Introduction AbstractFeatures General Description On Board Memory MCU Operating ModeExternal Bus interface Connectors MCU ClocksUser Buttons MCU PinsPower Supply User LEDs and optional LCDInstallation AC plug adapterStarter kit status after power on Jumper Settings Jumper Description / Function Type DefaultJumper settings UART4 RTS CTSDefault Jumper Settings Jumper LocationSoftware Installation Installation of Softune Workbench Softune Workbench start menu locationSoftune Workbench V6 IDE MCU Operating Mode Jumpers and SwitchesDIP switch Setting Logical value MCU Operating-Mode S5FlexRay CC Operating Mode FlexRay CC Operating-Mode S2FlexRay CC SPI Settings S1 FlexRay CC SPI SettingsJumper Setting Description Switch Setting DescriptionPower Switch Power supply configurationsVoltage Test Points Regulator Test point VoltageMCU Analogue Power Supply Voltage MCU Power Supply VoltageMCU Power Supply SK-91F467-FLEXRAY MCU ADC Supply FlexRay CC Power Supply Voltage at SK-91F467-FLEXRAYFlexRay CC Supply MCU-FlexRay CC Connection at SK-91F467-FLEXRAY JP7Channel a 10 MCU-FlexRay CC Connection11 FlexRay CH-A Configuration Channel B12 FlexRay CH-B Configuration 13 FT1080 Control Settings 3 FT1080 Control Settings S614 FT1080 Connection to MCU LIN / RS-232 Uart CAN0 CAN215 CAN-MCU connection 16 UART2 Settings Uart17 UART4 Settings Uart 4 Flash programming18 UART5 Settings DIP switch Setting Description User DIP Switch 8 Bit S4User Push Buttons INT0, INT1, INT2 and ICU0/TIN0 22 Reset Connections Reset Generation23 Supply Monitor Settings 24 Reset Uart Selection By default the Uart reset is disabledUart / LIN Connector X1, X4 ConnectorsPower Connector Pin Number Pin Signal DescriptionCan Connector Signals Can Connector X9, X10FlexRay Connector X2 FlexRay Connector SignalsFlexRay Physical Layer Module Connector X3 FlexRay Physical Layer ModulesLED/LCD Signals USER-LEDs and optional LC-Display D1-D16, J6In-Circuit Programming Connector In-Circuit-Programming ConnectorMCU Pin Connectors J1-J4 Connector MCU PinsExternal Bus Connectors X13, X14 4.9.1 VG96ABC DIN 41612 VG96 X13 SignalsVG48 X14 Signals Distance between VG-Connectors2 VG48ABC DIN 41612 Introduction to Softune Workbench Softune Workbench main windowSK-91F467-FLEXRAY Getting Started Enter the folder myapplication Project Start-upCreate a New Project Edit myapplication.prjOpen Softune Workbench workspace *.wsp Use Active Configuration Mondebuginternal Select Active Configuration MondebugSoftune Workbench Linker Mapping Use Active configuration Standalone Start Softune Monitor Debugger via the Debug CommandSoftune Workbench Monitor Debugger General DescriptionU1, MCU MB91F467DA DIP switch S5, default all OFF User LEDsSWB debugging window Basic Debugger Features Advanced Monitor Debugger Features Use the button INT0 on the SK-91F467-xxx for Abort functionExample SK-91F467-FLEXRAY Getting Started Memory Map of Softune Workbench Monitor debugger Memory Configuration for User ApplicationsMemory Type Used for Areas Sections Checklist for project configuration 0x0080.0000 0x009F.FFFFFlash Programming Programming internal Flash of MB91F467DA seriesFMEMCU-UG-910017-11 Fujitsu Microelectronics Europe GmbH FME Flash Programmer output message window Trouble shooting Trouble shootingSilk-Plot of the Board Top SideBottom Side Board Layout Bottom SideSK-91F467-FLEXRAY PCB HistoryHistory PCB Appendix Related ProductsInformation on the WWW Tables Trouble shooting History PCB Figures Abbreviations Usart