Fujitsu MB88121 SERIES manual U1, MCU MB91F467DA DIP switch S5, default all OFF, User LEDs

Page 53

SK-91F467-FLEXRAY V1.1

Getting Started

Make sure you have connected the “SK-91F467-xxx” starter kit and your monitor-kernel is stored in the internal flash memory of the MB91F467DA series at the starter kit. Then power up and reset the starter kit. Check the following configurations:

1) Correct CPU Mode selection (DIP-Switch S5)

After Power on the Monitor debugger indicates via the 8 user-LEDs the current status. The following status indications exist. Ensure that the CPU is working in normal RUN Mode (DIP-Switch S5 position all OFF)

U1, MCU MB91F467DA

DIP switch S5, default all OFF

Figure 5-7: MB91F467D and mode pin DIP switch

2) Correct start-up of the monitor debugger

8 User LEDs

Figure 5-8: Reset button and user LED

Reset

In case of any other status indication push the reset button or check chapter 6.6.1 for detailed information.

Start the debugger by double clicking the “Mondeb_57K6_com1.sup” entry in the project/debug tree - or by using “Debug – Start Debug” from the menu. You should see a progress bar indicating the download process.

If no process is indicated an error message will occur (“e.g. Invalid communication status”). Double-check the settings again as explained above. Also make sure the evaluation-board is powered on, ready to use and the RS232-cable is connected properly. Also see the trouble- shooting section in the appendix.

© Fujitsu Microelectronics Europe GmbH

- 53 -

FMEMCU-UG-910017-11

Image 53
Contents MB88121 Series MB91460 Series Revision History Date IssueNo Liability for Consequential Damages Warranty and DisclaimerContents Connectors Trouble Shooting SILK-PLOT of the Board Abstract IntroductionFeatures General Description External Bus interface Connectors MCU Operating ModeOn Board Memory MCU ClocksPower Supply MCU PinsUser Buttons User LEDs and optional LCDAC plug adapter InstallationStarter kit status after power on Jumper Description / Function Type Default Jumper SettingsUART4 RTS CTS Jumper settingsJumper Location Default Jumper SettingsSoftune Workbench start menu location Software Installation Installation of Softune WorkbenchSoftune Workbench V6 IDE DIP switch Setting Logical value Jumpers and SwitchesMCU Operating Mode MCU Operating-Mode S5FlexRay CC Operating-Mode S2 FlexRay CC Operating ModeFlexRay CC SPI Settings FlexRay CC SPI Settings S1Power Switch Switch Setting DescriptionJumper Setting Description Power supply configurationsRegulator Test point Voltage Voltage Test PointsMCU Power Supply SK-91F467-FLEXRAY MCU Power Supply VoltageMCU Analogue Power Supply Voltage FlexRay CC Supply FlexRay CC Power Supply Voltage at SK-91F467-FLEXRAYMCU ADC Supply JP7 MCU-FlexRay CC Connection at SK-91F467-FLEXRAY10 MCU-FlexRay CC Connection Channel aChannel B 11 FlexRay CH-A Configuration12 FlexRay CH-B Configuration 14 FT1080 Connection to MCU 3 FT1080 Control Settings S613 FT1080 Control Settings 15 CAN-MCU connection CAN0 CAN2LIN / RS-232 Uart Uart 16 UART2 SettingsUart 4 Flash programming 17 UART4 Settings18 UART5 Settings User Push Buttons INT0, INT1, INT2 and ICU0/TIN0 User DIP Switch 8 Bit S4DIP switch Setting Description 23 Supply Monitor Settings Reset Generation22 Reset Connections By default the Uart reset is disabled 24 Reset Uart SelectionPower Connector ConnectorsUart / LIN Connector X1, X4 Pin Number Pin Signal DescriptionFlexRay Connector X2 Can Connector X9, X10Can Connector Signals FlexRay Connector SignalsFlexRay Physical Layer Modules FlexRay Physical Layer Module Connector X3USER-LEDs and optional LC-Display D1-D16, J6 LED/LCD SignalsMCU Pin Connectors J1-J4 In-Circuit-Programming ConnectorIn-Circuit Programming Connector Connector MCU PinsVG96 X13 Signals External Bus Connectors X13, X14 4.9.1 VG96ABC DIN 416122 VG48ABC DIN 41612 Distance between VG-ConnectorsVG48 X14 Signals Softune Workbench main window Introduction to Softune WorkbenchSK-91F467-FLEXRAY Getting Started Create a New Project Project Start-upEnter the folder myapplication Edit myapplication.prjOpen Softune Workbench workspace *.wsp Select Active Configuration Mondebug Use Active Configuration MondebuginternalSoftune Workbench Linker Mapping Start Softune Monitor Debugger via the Debug Command Use Active configuration StandaloneGeneral Description Softune Workbench Monitor DebuggerUser LEDs U1, MCU MB91F467DA DIP switch S5, default all OFFSWB debugging window Basic Debugger Features Use the button INT0 on the SK-91F467-xxx for Abort function Advanced Monitor Debugger FeaturesExample SK-91F467-FLEXRAY Getting Started Memory Type Used for Areas Sections Memory Configuration for User ApplicationsMemory Map of Softune Workbench Monitor debugger 0x0080.0000 0x009F.FFFF Checklist for project configurationProgramming internal Flash of MB91F467DA series Flash ProgrammingFMEMCU-UG-910017-11 Fujitsu Microelectronics Europe GmbH FME Flash Programmer output message window Trouble shooting Trouble shootingTop Side Silk-Plot of the BoardBoard Layout Bottom Side Bottom SideHistory PCB PCB HistorySK-91F467-FLEXRAY Related Products AppendixInformation on the WWW Tables Trouble shooting History PCB Figures Usart Abbreviations