Xerox 721P85600 manual Delta

Page 47

PREINSTALLATION

Table 3-6.DocuPrint 96/DocuPrint 96MX Environmental and

 

electrical requirements (continued)

 

 

 

Environmental requirements

 

 

 

 

 

Printer

U.S. and Canada,

120/240 VAC or

 

60Hz:

120/208 VAC;

 

 

50 amp service;

 

 

NEMA 14-50R

 

 

KVA 7.3 (operating)

 

International, 50 Hz

380, 400, 415 VAC

 

(WYE):

(3 phase, 5 wire);

 

 

20 amp service (WYE)

 

International, 50 Hz

220, 230, 240 VAC (3 phase, 4 wire);

 

(DELTA):

30 amp service (DELTA)

 

 

 

 

 

Audible noise

Standby:

Continuous: 52 dB (A)

 

 

Impulse: N/A

 

Operating:

Continuous: 67dB (A)

 

 

Impulse: 72dB (A)

 

 

 

Optional peripheral cabinet

U.S. and Canada,

208/240 VAC (1 phase) or

 

60Hz:

208/220 VAC (Line 1 to line 2);

 

 

 

 

15 amp service;

 

 

NEMA6-15R or

 

 

ANSI C73, 20R

 

 

KVA .9 in both standby and operating

 

International, 50 Hz:

200/230 VAC (1 phase);

 

 

15 amp service

 

 

 

Optional bypass transport

The power requirements for the bypass transport module are all

 

satisfied by the DocuPrint 96/DocuPrint 96MX LPS printer module.

 

 

Agency certification

UL, CSA, CE Mark, EC 950, VDE 0871 (Level AQ) and 0875, EEC

 

82/499, and CISPR 22 Class A.

 

 

 

XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE

3-17

Image 47
Contents April 1998 721P85600 Page Related Publications Number Related publicationsPage Table of Contents Installation Index PostinstallationGlossary Viii What this guide contains IntroductionIntroduction LPS Operations Reference Xerox DocuPrint 96/DocuPrint 96MXLPS Operator Guide Xerox DocuPrint 96/DocuPrint 96MX LPS PDL ReferenceUser Guide Xerox DocuPrint 96/DocuPrint 96MX LPS Forms Creation GuideCard LPS Message GuideXerox or Xerox Limited responsibilities ResponsibilitiesCustomer responsibilities Installation planning checklist Week Activity Reference Responsibility Date completed Installation planning checklistXvii Xviii Xerox DocuPrint 96/DocuPrint 96MX LPS LPS overviewSystem controller components Base componentsKeyboard display System user interface keyboard displayXerox DocuPrint 96/DocuPrint 96MX printer components LPS Overview Micr line Magnetic Ink Character Recognition MicrOffline interfaces System controller optionsInterface options Online interfaceHIP-accessed interfaces Floppy disk drive Expanded system disk memoryEnhanced graphics ink and font memory Egifm Bypass transport Printer optionsFeeder stacker Input enablement device Printer ConfigurationsPrinter + Inverter Feeder Stacker + Feeder Stacker Host Resident software packagesLPS delivery requirements PreinstallationSystem controller Preinstallation Printer Printer with an inverter feeder/stacker and a feeder/stacker Preinstallation Shared space Space planning guidelinesClearance space requirements Back-to-back shared service area space Face-to-face shared service area space Cable lengths Power cable and data cable length10.Cable enter/exit locations top view Cable locationsEfficiency of use Delivery access requirementsPreinstallation Passage or doorway a width Minimum passage B width Turning radius for printer separated and upendedOn dolly Passage or doorway a width Minimum passage B width Turning radius for inverter Feeder/Stacker modulePreinstallation Environmental/electrical requirements Delta Electrical environment Voltage/current Receptacle Printer power receptacle requirements10. Printer 50 Hz only WYE connection for 380 V Service outlet Configuration Measurement Nominal RangeHz WYE printer outlet voltages Hz Delta printer outlet voltages RMS Hz printer outlet voltages12.Printer power cord 60 Hz installation for 50 amp Nema Hz system power cord configurationsThird party connections Interface requirementsFinishing and feeding equipment Channel-attachedSystem training TrainingOperator training Preinstallation Fonts Ordering supplies for installationPaper Tapes Dry ink tonerFuser agent DeveloperSpace planning templates 14.Space planning templates top views 15.Space planning templates top views Page Grid Pattern 1/4 inch represents one foot Page Installation process InstallationInstallation responsibilities Software kits Documentation and software kitsDocumentation Page Xerox support services PostinstallationXerox Customer Support Center Customer Service Support Center Font U.S. only Xerox Font CenterXerox Customer Documentation Catalog Xerox Documentation and Software Services Xdss Xerox Supplies Order Service Meter reading and reporting Routine maintenanceTypes of applications available Identifying new applicationsConsumable supplies, paper Description Part number Paper Consumable supplies tableGummed Consumable supplies, paper Description Part numberTransparencies High Speed LabelsCover stock Cleaning suppliesConsumable supplies, paper Description Part number Tab stockStock Reverse Alternating 5000 2500 3R4228 Supplies checklist Glossary Glossary Glossary Glossary Glossary Glossary Glossary Glossary Glossary Glossary GLOSSARY-11 Glossary GLOSSARY-13 Glossary GLOSSARY-15 Glossary GLOSSARY-17 Glossary GLOSSARY-19 Glossary GLOSSARY-21 Glossary GLOSSARY-23 Glossary GLOSSARY-25 Laser HposIps Ppm LpiGlossary GLOSSARY-29 Page QGH Page Page 522&835,172&835,170/36,167$//$7,213/$11,1**8