4635 LPS OVERVIEW
Heat dissipation, printer | Operating: 28,140 Btu per hour  | |
  | Standby: 4,454 Btu per hour  | |
Heat dissipation, system controller | 3,754 Btu per hour  | 
  | 
Heat dissipation, optional peripheral  | 
  | 
  | 
cabinet (fully configured) | 3,195 Btu per hour  | 
  | 
Electrical requirements | 
  | 
  | 
  | 
  | |
  | For more information on 4635 LPS electrical requirements,  | |
  | including power cord and outlet specifications, refer to the Xerox  | |
  | 4635 LPS Installation Planning Guide.  | |
System controller  | U.S./Canada, 60 Hz:  | 208/240 (1 phase) or 208/220 VAC  | 
  | 
  | (line 1 to line 2)  | 
  | 
  | 15 amp service  | 
  | 
  | NEMA   | 
  | 
  | KVA 1.1 (operating)  | 
  | International, 50 Hz:  | 200/230 VAC (1 phase)  | 
  | 
  | 15 amp service  | 
  | 
  | Power connector per local codes  | 
Printer | U.S./Canada, 60 Hz:  | 120/240 VAC or 120/208 VAC  | 
  | 
  | 50 amp service  | 
  | 
  | NEMA   | 
  | 
  | KVA 7.3 (operating)  | 
  | International, 50 Hz:  | 380, 400, 415 VAC (3 phase, 5 wire)  | 
  | (WYE):  | 20 amp service (WYE)  | 
  | International, 50 Hz:  | 220, 230, 240 VAC (3 phase, 4 wire)  | 
  | (DELTA):  | 30 amp service (DELTA)  | 
Optional bypass transport | The bypass transport uses the Printer module as its power  | |
  | source, therefore all power requirements for the bypass transport  | |
  | are satisfied by the 4635 LPS.  | |
Optional peripheral cabinet | U.S./Canada, 60 Hz:  | 208/240 VAC (1 phase) or 208/220  | 
  | 
  | (line 1 to line 2)  | 
  | 
  | 15 amp service  | 
  | 
  | NEMA 6 to 15R or ANSI C73, 20R  | 
  | 
  | KVA .9 in both standby and operating  | 
  | International, 50 Hz:  | 200/230 VAC (1 phase)  | 
  | 
  | 15 amp service  | 
  | 
  | Power connector per local codes  | 
Agency certification | UL, CSA, IEC, VDE  | 
  | 
XEROX 4635 LASER PRINTING SYSTEM LPS PRODUCT REFERENCE  |