4) Open the scanning unit (printer cover) to display the color pattern. Only the ON/OFF button is enabled.
5) Press the ON/OFF button to return to the service mode menu selection.
<Waste ink amount setting procedures>
Set the waste ink amount data to a replaced new EEPROM after the logic board is replaced in servicing.
1)Before replacement of the logic board ass'y, check the waste ink amount in EEPROM information print. [See
2)In the waste ink amount setting mode, press the Stop/Reset button the specified number of time(s) according to the waste ink absorber whose value should be transferred to the replaced new EEPROM. (Only the main waste ink absorber for the MP800)
Time(s) | Waste ink absorber | Remarks |
0 times | Main waste ink absorber |
|
1 time | Platen waste ink absorber | Not valid for the MP800 |
| Both the main and platen waste ink |
|
|
|