3 times | Orange (Alarm) | US | Not supported |
4 times | Green (COPY) | Europe | Supported |
5 times | Orange (Alarm) | Australia | Supported |
6 times | Green (COPY) | Asia | Supported |
7 times | Orange (Alarm) | China | Supported |
8 times | Green (COPY) | Taiwan | Supported |
9 times or | Orange (Alarm) | Return to the menu selection |
|
more |
| ||
|
|
|
Note: After setting the destination without logic board replacement, be sure to initialize the EEPROM (to prevent
the Print Beam settings or copy paper settings from being different from the destination settings).
Confirm the model name and destination in service test print or EEPROM information print. [See
<Button and LCD test procedures>
Confirm the operation after replacement of the operation panel unit, logic board, or LCD.
1) Press the Stop/Reset button. The LCD turns blue, waiting for a button to be pressed.
2) Press each button on the operation panel.
The LCD is divided into segments, representing each button. The color of a segment corresponding to the pressed button changes to red.
3)When all the buttons are pressed, the entire LCD changes to a full red screen, and no further pressing of the buttons is accepted.