dbx Pro 266XL manuel dutilisation Compressor Section, Overeasy Switch

Page 8

6

COMPRESSOR SECTION

Note: Setting the Compressor RATIO to 1:1 will turn the Compressor off, regardless of the setting of the

Compressor THRESHOLD control and BELOW/OVEREASY/ABOVE LED status. Setting the Compressor

THRESHOLD control to +20dB will prevent all but the highest level peaks from being compressed.

OVEREASY® Switch

Depress this switch to select the OverEasy® compression characteristic. The amber THRESHOLD LED turns on when the signal is in the OverEasy region. When the switch is out, the 266XL operates as a hard-knee compressor, and the amber LED does not light.

Compressor THRESHOLD Control and LEDs (BELOW/OVEREASY/ABOVE) Adjust this control to set the threshold of compression from - 40dB to +20dB. In hard-

knee mode, the threshold of compression is defined as the point above which the out- put level no longer changes on a 1:1 basis with changes in the input level.

In OverEasy mode the threshold of compression is defined as the middle of the

OverEasy threshold region, that is, “half-way” into compression.

The three THRESHOLD LEDs indicate the relationship of the input signal level to the threshold of compression. The green LED lights when the signal is BELOW threshold, the red LED lights when the signal is above threshold, and the yellow LED lights when the OVEREASY switch is depressed and the input signal is in the OVEREASY range.

The 266XL's OverEasy compression permits extremely smooth, natural sounding com- pression, without artifacts, due to the gradual change of compression around the threshold. With OverEasy compression, input signals begin to gradually activate the 266XL's internal gain change circuitry as they approach the THRESHOLD reference level. They do not get fully processed by the RATIO, ATTACK and RELEASE con- trols until they have passed somewhat above the THRESHOLD reference level. As the signal level passes the THRESHOLD level, processing increases until it is fully processed to the extent determined by the control settings.

In hard-knee mode, the 266XL can provide abrupt compression effects as well as hard- limiting applications. Note that when in hard knee mode the amber LED will not light as the input signal passes across the threshold. The signal is either being compressed (over threshold) or it is not being compressed (under threshold).

Note: Even though no input signal is being applied, it is normal for the LEDs to flicker on when the power is applied or removed.

Compressor RATIO Control

Adjust this control to set the amount of compression applied to the input signal. Clockwise rotation of this control increases the compression ratio from 1:1 (no com- pression) up to :1 (where the compressor can be considered to be a peak limiter, especially with faster ATTACK settings).

266XL Compressor / Gate

Image 8
Contents 266XL Compressor / Gate Important Safety Instructions Lithium Battery Manual Contents English Contents266XL Compressor / Gate Common Gating Applications IntroductionCommon Compressor Applications Operating Controls Front PanelOvereasy Switch Compressor SectionEXPANDER/GATE Section Compressor Attack and Release ControlBasic Connection Connecting the 266XL to Your System IEC AC Power cord receptacleTechnical Support and Factory Service Registration Card and User FeedbackFrançais Page Table DES Matieres Applications courantes de la compression Applications courantes du GateContrôles Touche Stereo CoupleTouche Bypass Afficheur Gain Reduction dBBouton Ratio du compresseur Section CompresseurTouche Overeasy Section EXPANSEUR/GATE Réglage des Temps Dattaque et de RelachementTouche Automatique Bouton Threshold et Leds BELOW/ABOVE de lexpanseur/GateSorties Jack Voies 1 et Jack dinsert Side ChainConnexion DU 266XL a Votre Systeme Support Technique ET APRÈS-VENTEConnecteur dalimentation Connexions à vos équipements à l’aide de jacks 6.35 ou XLRCarte DE Garantie Deutsch Page Inhalt Einleitung Bedienelemente FrontplatteKOMPRESSOR-SEKTION Compressor RATIO-ReglerEXPANDER/GATE-SEKTION AUTO-TasteEXPANDER/GATE RATIO-Regler Input Eingangsbuchsen Channel 1 und ChannelOutput Ausgangsbuchsen Channel 1 und Channel Operating LEVEL-TasteIEC-Kaltgerätebuchse Service UND KundendienstAnschliessen DES DBX 266XL AN Ihre Anlage REGISTRIERUNGS- UND Antwortkarte Español Page Contenido DEL Manual Aplicaciones comunes de compuertas IntroduccionAplicaciones comunes del compresor Controles Conmutador Stereo CoupleConmutador y Bypass Medidor Gain Reduction dBSeccion Compressor Conmutador OvereasyControl Compressor Threshold y LEDs -/0/+ Control Compressor RatioSeccion EXPANDER/GATE Controles Compressor Attack y ReleaseConmutador Auto Control EXPANDER/GATE Threshold y LEDs -/+Control EXPANDER/GATE Ratio Jacks de entrada Input Canal 1 yJacks de salidaOUTPUT Canal 1 y Conmutador Operating LevelApoyo Tecnico Y Servicio DE Fabrica Tomacorriente CA tipo IECTarjeta DE Registro Y Reacciones DE LOS Usuarios Threshold 266XL Compressor / Gate 266XL Compressor / Gate Harman International Company
Related manuals
Manual 44 pages 57.48 Kb