| DR300 Operator Manual |
| Chapter 9 - Online Programming |
| |
|
|
|
|
|
|
| Data Code |
|
|
| |
|
|
|
|
|
|
| Digit | Designated Item |
| Designated Description |
|
| Position |
|
|
|
|
| 1 | Field Designation | 4 | : 2D Bar Code |
|
| 2 | Field Designation | 1 | : Data Code |
|
| 3 | Mode | 1 | : Numeric Mode |
|
|
| (Format ID) | 2 | : Alpha (upper case mode) |
|
|
|
| 3 | : Alphanumeric & Notation |
|
|
|
| 4 | : Alphanumeric |
|
|
|
| 5 | : |
|
|
|
|
| ||
| 4, 5 | Vertical Position | 0000: Input only and no printing field |
| |
| 6, 7 |
| 0001 ~ 2848: Vertical position (dot) |
| |
| 8, 9 | Horizontal Position | 001 ~ 640: Horizontal position (dot) |
| |
| 10 |
|
|
|
|
| 11 | Rotation | 0 | : 0º |
|
|
|
| 1 | : 90º |
|
|
|
| 2 | : 180º |
|
|
|
| 3 | : 270º |
|
| 12, 13 | Module | 01 ~ 32 : Cell Size (dot) |
| |
|
|
| (refer to module size notes) |
| |
| 14, 15 | Reserved | 00 |
| |
| 16, 17 | Error Correction | Error Correction Level |
| |
|
|
| 00 : ECC000, 05 : ECC050, 08 : ECC080 |
| |
|
|
| 10 : ECC100, 14 : ECC140, 20 : ECC200 |
| |
| 18 | Reserved | [0] Fixed |
| |
| 19 ~ | Reserved | All [0] |
|
*Module
To define the cell size:
1.The definition of 01, 02 dots are acceptable but may face difficulties for decoding/reading.
2.Use larger module for better printing quality.
Error Correction
To define the error correction level when barcode is damaged or tampered. Connection level is high with larger correction definition.
64