Xantrex Technology PROwatt 1000 Reading the Front Panel Indicators, Battery Voltage Indicator

Page 44

Operation

Reading the Front Panel Indicators

Battery Voltage Indicator

The battery VOLTS indicator shows the voltage at the input terminals of the PROwatt 1000. At low input currents, this voltage is very close to the battery voltage. At high input currents, this voltage is lower than the battery voltage because of the voltage drop across the cable and connection.

During operation, the voltage should remain in the green area.

If voltage goes into the top or bottom red area, the inverter may shut down.

Battery Current Indicator

The AMPS indicator shows the current that the inverter is drawing from the battery. It does not indicate current drawn by other loads also connected to the battery.

For long-term operation, the current should remain in the green area.

Short-term operation is possible with the current in the yellow area.

If the current rises to the red area, the inverter reduces its output voltage to protect itself.

OVER TEMP Indicator

The OVER TEMP LED (light emitting diode) indicates that the inverter has shut itself down because it has overheated. The inverter may overheat because it has been operated at power levels above its continuous output rating, or because it has been installed in a location that does not allow it to dissipate heat properly. The inverter will restart automatically once it has cooled off.

OVER LOAD Indicator

The OVER LOAD LED indicates that the inverter has shut itself down because of severe overload, an AC wiring fault, or another AC voltage source connected to the output.

If the OVER LOAD LED comes on, turn off the On/Off switch, correct the fault condition, and then turn the switch back on.

Do not turn the inverter on again until you have corrected the fault condition.

4–4

Image 44
Contents PROwatt 1000 Inverter Date and Revision About This Guide PurposeScope AudienceAbout This Guide Conventions Used Related InformationPage General Precautions Explosive Gas PrecautionsProwatt Precautions When Working With BatteriesPrecautions For Using Rechargeable Appliances Contents Troubleshooting OperationSpecifications Battery Types and SizesAlternators and Charging Systems Product and System InformationPage Introduction Quality Power Ease of UseComprehensive Protection Page Features PROwattMaterials List Feature Description Front Panel AC EndBack Panel DC End Back Panel DC EndRemote On/Off Switch REM O TE SW ITC HPage Installation Safety Instructions Installation CodesInstallation Tools and Materials ToolsOverview of Installation Steps Choosing a Charging System Designing Your InstallationCalculating Battery Requirements Choosing a Location CoolMaintain correct wiring polarity Connecting to an Existing AC CircuitAC Wiring Precautions AC Wiring Procedure To make a permanent connection to existing AC wiringInstalling Transfer Switches in AC Circuits Bottom View of Inverter Showing AC Terminal BlocksSimple Transfer Switching Installing the Remote On/Off Switch To install the remote On/Off switchMounting the Inverter To mount the ProwattConnecting the Chassis Ground Grounding LocationsFixed Location residential, for example Connect Connecting DC CablesCabling Guidelines Fuse/Circuit Breaker Sizing Guidelines To select the correct fuse type and sizeCabling Procedure 1000To connect the DC cables ALLInstallation Connecting DC Cables Page Operation Turning the Inverter On and Off Operating Several Loads at OnceTurning the Inverter Off Between Charges To turn the inverter on and off from its front panelUsing the Remote On/Off Switch Testing the GFCI-Protected AC OutletTo operate the inverter from the remote On/Off switch To test the Gfci protectionBattery Current Indicator Reading the Front Panel IndicatorsBattery Voltage Indicator Input Voltage Power OutputOperating Limits Trouble Loads Problem LoadsInverter Loads Battery Charging Frequency Routine Maintenance Page Troubleshooting Television Reception Common ProblemsBuzz in Audio Equipment Troubleshooting Reference Problem Possible Cause SolutionProblem Possible Cause Solution Specifications Physical Inverter Dimensions Remote On/Off SwitchElectrical Performance Inverter Battery Types SizesDeep-Cycle Lead-Acid Batteries Battery TypesAutomotive Starting Batteries Battery Size To determine how much battery capacity you need Estimating Battery RequirementsBattery Sizing Example Battery Sizing Worksheet Appliance Consumption Per day = a x BUsing Multiple Batteries Two Batteries Connected In ParallelTwo Separate Battery Banks To VehicleBattery Tips Battery Voltage State of Charge Page Alternators Charging SystemsCharging With an Engine Alternator Using a Standard Vehicle AlternatorCharging System Requirements Charging From AC Power Using an Alternator ControllerUsing a High-Output Alternator Charging From Alternative Energy SourcesPage Product InformationSystemWarranty Return Material Authorization Policy Return Material ProcedureInformation About Your System AGMRemote On/Off Switch Mounting Template Figure D-1 Remote On/Off Switch Mounting TemplatePage Index Index Index-3 Index-4