Overview of Installation Steps

DC fuses and fuse holders

AC cable (2-conductor-plus-ground cable), sized appropriately for load and application (if you are connecting to an existing AC circuit)

1/2 inch cable clamp (if connecting to an existing AC circuit)

AC transfer switch (if connecting to an existing AC circuit that also uses power from another AC source)

Appropriately sized copper cable for the chassis ground

Battery isolator (if connecting to a multiple-battery system)

Battery selector switch*

Alternator controller*

High-output alternator*

*Consult Appendix B and Appendix C to determine whether you need these components.

Overview of Installation Steps

Installing the PROwatt 1000 is straightforward. Here’s a summary of the seven main steps:

1.Design the installation: calculate battery capacity and charging requirements.

2.Choose a location.

3.Connect to an existing AC circuit (if required).

4.Install the remote On/Off switch.

5.Mount the inverter.

6.Connect the chassis ground.

7.Connect the DC cables.

3–3

Image 25
Contents PROwatt 1000 Inverter Date and Revision Purpose About This GuideScope AudienceAbout This Guide Related Information Conventions UsedPage Explosive Gas Precautions General PrecautionsPrecautions For Using Rechargeable Appliances Precautions When Working With BatteriesProwatt Contents Operation TroubleshootingBattery Types and Sizes SpecificationsAlternators and Charging Systems Product and System InformationPage Introduction Ease of Use Quality PowerComprehensive Protection Page PROwatt FeaturesMaterials List Front Panel AC End Feature DescriptionBack Panel DC End Back Panel DC EndREM O TE SW ITC H Remote On/Off SwitchPage Installation Installation Codes Safety InstructionsInstallation Tools and Materials ToolsOverview of Installation Steps Calculating Battery Requirements Designing Your InstallationChoosing a Charging System Cool Choosing a LocationAC Wiring Precautions Connecting to an Existing AC CircuitMaintain correct wiring polarity To make a permanent connection to existing AC wiring AC Wiring ProcedureBottom View of Inverter Showing AC Terminal Blocks Installing Transfer Switches in AC CircuitsSimple Transfer Switching To install the remote On/Off switch Installing the Remote On/Off SwitchMounting the Inverter To mount the ProwattGrounding Locations Connecting the Chassis GroundCabling Guidelines Connecting DC CablesFixed Location residential, for example Connect To select the correct fuse type and size Fuse/Circuit Breaker Sizing Guidelines1000 Cabling ProcedureALL To connect the DC cablesInstallation Connecting DC Cables Page Operation Operating Several Loads at Once Turning the Inverter On and OffTurning the Inverter Off Between Charges To turn the inverter on and off from its front panelTesting the GFCI-Protected AC Outlet Using the Remote On/Off SwitchTo operate the inverter from the remote On/Off switch To test the Gfci protectionBattery Voltage Indicator Reading the Front Panel IndicatorsBattery Current Indicator Operating Limits Power OutputInput Voltage Inverter Loads Problem LoadsTrouble Loads Battery Charging Frequency Routine Maintenance Page Troubleshooting Buzz in Audio Equipment Common ProblemsTelevision Reception Problem Possible Cause Solution Troubleshooting ReferenceProblem Possible Cause Solution Specifications Electrical Performance Inverter Dimensions Remote On/Off SwitchPhysical Inverter Sizes Battery TypesAutomotive Starting Batteries Battery TypesDeep-Cycle Lead-Acid Batteries Battery Size Battery Sizing Example Estimating Battery RequirementsTo determine how much battery capacity you need Appliance Consumption Per day = a x B Battery Sizing WorksheetTwo Batteries Connected In Parallel Using Multiple BatteriesTo Vehicle Two Separate Battery BanksBattery Tips Battery Voltage State of Charge Page Charging Systems AlternatorsCharging System Requirements Using a Standard Vehicle AlternatorCharging With an Engine Alternator Using an Alternator Controller Charging From AC PowerUsing a High-Output Alternator Charging From Alternative Energy SourcesPage InformationSystem ProductWarranty Return Material Procedure Return Material Authorization PolicyAGM Information About Your SystemFigure D-1 Remote On/Off Switch Mounting Template Remote On/Off Switch Mounting TemplatePage Index Index Index-3 Index-4