Xantrex Technology XDI2048 manual User Line Connector, User Line Wiring, User Line Connection

Page 32

Rack Mount Frame Assembly and Installation

User Line Connector

The user-line is a 6-position wire clamp connector adjacent to the DC input connector. Table 2-1 lists user functions and associated terminal numbers.

User Line Wiring

Use twisted pairs of 22-24 AWG for connections. Before making any connections, ensure power to the rack has been disconnected. Carefully route the wires away from high power load cables to minimize noise effects on signal integrity.

User Line Connection

Use this table to wire appropriate signals.

Table 2-1

User Line Connection

 

 

 

 

 

 

 

 

Terminal

Label

I/O

Logic Level

Function

 

 

 

 

 

 

1

User line return

GND

GND

GND reference

2

User shutdown

Input

Active high

Shuts down

 

 

 

 

 

inverter

3

Fault Flags

Output

Active high

Inverter faults

4

AUX flag

Output

N/A

User configurable

5

Inverter flag

Output

Active high

Inverter on-line

6

Not used

N/A

N/A

N/A

User line voltages are below:

 

 

 

 

 

 

 

 

Inputs

 

 

 

 

 

High

1.25 V to 5 V

 

 

 

 

Low

0.0 V to 1.25 V

 

 

 

 

 

 

 

 

 

 

Outputs

 

 

 

 

 

High

5 V

 

 

 

 

Low

1.5 V max.

 

 

 

 

 

 

 

 

 

 

2-12

TM-DIOP-01XN-01

Image 32
Contents XDI2048 2kVA/1.5kW Page Xantrex Datacom Inverter Date and Revision Purpose ScopeAudience OrganizationConventions Used Related InformationImportant Safety Instructions Page Contents Inverter Module Installation and Operation Troubleshooting Remote Communication & MonitoringSpecifications Warranty and Product InformationFigures Xii Tables Xiv Introduction Description Features and OptionsInverter Information Features and Functions Ethernet InformationPart Number and Ordering Information XDI2048HV-RMAssembly Initial Inspection Packing ListPackaging for Shipping or Storage 2Shipping or Storage Carton LabelIntroduction Rack Mount Frame Rear ViewInstallation Into Cabinet Style Equipment Racks Location, Mounting and VentilationInstallation into Relay Racks Installing into Relay RacksDC Input Wire Connection DC Input PowerInput Connector and Cables Connecting the Input Wires AC Load and Signal Line Connection AC Output Connector Load Wiring AC Output Voltage WireLoad Connection User Line Connection OverviewUser Line Connector User Line WiringUser Line Connection User Line ConnectionCAN/SYNC Connection CAN/SYNC ConnectorSpecifications Terminals Function CAN/SYNC WiringCAN/SYNC Pin-out Connection Schemes Stand-Alone OperationParallel Operation ConnectionParallel Operation Load Terminal Voltage Split Phase OperationSplit-Phase Operation Three Phase Operation 33-Phase ConfigurationsWiring Output Configuration Terminals Model VoltagePhase Synchronization and Signal Wiring 103-Phase Sync ConnectionPhase, 3-Wire Delta Output Wiring Phase, 3-Wire Y-Connection Output WiringPhase, 4-Wire Y-Connection Output Wiring Ethernet PortPage Operation Installation into Rack Mount Frame Installing an Inverter into a Rack 2Inverter Front PanelSystem Startup Operation of Inverter ModuleTheory of Operation Standby Mode Cooling Fans2User Line Pins User InterfaceFront Panel User LinesProtections and Alarms OverviewInput Voltage Protection Output Voltage ProtectionOverload Protection 3Overload curveOver Temperature Protection OTP Internal DiagnosticsShort-circuit Protection Over-Current protectionIncorrect Connection Protection Output AC AlarmFuses and Grounding Maintenance To Clear an Alarm4Replacing the Fan Filters Monitoring Web-enabled User Interface Initial SetupInitial Setup Ethernet Interface PCBHow to Setup For the First Time Hardware SetupSetting Default Value Ethernet Setup1Default Settings SettingValue Resetting2User Configured Settings Removing Unit’s Top Cover 3Reset SettingsSetting Reset Value Ethernet Reset Jumper Operating Instructions Network Connection5Network Setup Using Dhcp What Power On DoesPassword 6Password Confirmation BoxesAutomatic Power-On Email How to Use the Web InterfaceManage Object DescriptionSetup 8Setup Page of Web Interface5Setup Page of Web Interface Monitor 9Monitor Page of Web Interface6Monitor Page of Web Interface Shutdown Code Code Fault DescriptionAutomatic Shutdown Email TM-DIOP-01XN-01 Troubleshooting Unusual or Erratic Operation User DiagnosticsEmergency Shutdown Symptom Check Diagnostic Guide1Inverter Diagnostics 2Ethernet Diagnostics Specifications Inverter Specifications Electrical SpecificationsInverter Specifications Environmental Specifications Regulatory ApprovalsMechanical Specifications Inverter and Rack Mount Frame Dimensions Figure A-1Ethernet Specifications Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc