Xantrex Technology XDI2048 manual Inverter Specifications, Electrical Specifications

Page 80

Specifications

Inverter Specifications

Electrical Specifications

Input Voltage, Current, Power, Frequency Ranges

Nominal Input

- 48 VDC

Input Range

- 40 to - 60 V (meets all specification)

 

 

Safe Input Range

± 80 Vdc (will not damage unit)

 

 

Maximum Input Current

90 A (at 40 V in, max 3 kW surge output,

 

5 s max)

 

 

Nominal input Current

36 A (at 48 V input, 1500 W output)

 

 

Maximum Input Current Ripple

< 1% Input Current

 

 

DC Side Voice Band Noise Limit

less than 32 dBrnc (C-message

 

weighting)

 

 

Over Current Protection

electronic limit on input boost converter

 

stage, 60 A fuse on DC input Inverter

 

stage output fuse for extreme faults

 

 

Inrush Current Controlled

40 A typical at 48 V < (2x Irated)

Output Voltage, Current, Power, Frequency Ranges

Waveform

True Sinusoidal

THD

< 3% Typical for linear loads

 

 

Output Voltage

120 Vac/60 Hz

 

230 Vac/50 Hz

 

 

Voltage Regulation

< -10%/+4% over full operating range

 

 

Frequency Stability

± 0.05%

 

 

Frequency Accuracy

60/50 Hz ± 0.1%

 

 

Fully Isolated

input to output

 

 

Power Rating

2 kVA/1.5 kW Max, over full operating

 

temperature range

 

 

Peak Output Current Into

50Apk maximum for 120VAC

Nonlinear Load

25Apk maximum for 230VAC

A-2

TM-DIOP-01XN-01

Image 80
Contents XDI2048 2kVA/1.5kW Page Xantrex Datacom Inverter Date and Revision Purpose ScopeAudience OrganizationConventions Used Related InformationImportant Safety Instructions Page Contents Inverter Module Installation and Operation Troubleshooting Remote Communication & MonitoringSpecifications Warranty and Product InformationFigures Xii Tables Xiv Introduction Description Features and OptionsInverter Information Features and Functions Ethernet InformationPart Number and Ordering Information XDI2048HV-RMAssembly Initial Inspection Packing ListPackaging for Shipping or Storage 2Shipping or Storage Carton LabelIntroduction Rack Mount Frame Rear ViewInstallation Into Cabinet Style Equipment Racks Location, Mounting and VentilationInstallation into Relay Racks Installing into Relay RacksDC Input Wire Connection DC Input PowerInput Connector and Cables Connecting the Input Wires AC Load and Signal Line Connection AC Output ConnectorLoad Wiring AC Output Voltage WireLoad Connection User Line Connection OverviewUser Line Connector User Line WiringUser Line Connection User Line ConnectionCAN/SYNC Connection CAN/SYNC ConnectorSpecifications Terminals Function CAN/SYNC WiringCAN/SYNC Pin-out Connection Schemes Stand-Alone OperationParallel Operation ConnectionParallel Operation Load Terminal Voltage Split Phase OperationSplit-Phase Operation Three Phase Operation 33-Phase ConfigurationsWiring Output Configuration Terminals Model VoltagePhase Synchronization and Signal Wiring 103-Phase Sync ConnectionPhase, 3-Wire Delta Output Wiring Phase, 3-Wire Y-Connection Output WiringPhase, 4-Wire Y-Connection Output Wiring Ethernet PortPage Operation Installation into Rack Mount Frame Installing an Inverter into a Rack 2Inverter Front PanelSystem Startup Operation of Inverter ModuleTheory of Operation Standby Mode Cooling Fans2User Line Pins User InterfaceFront Panel User LinesProtections and Alarms OverviewInput Voltage Protection Output Voltage ProtectionOverload Protection 3Overload curveOver Temperature Protection OTP Internal DiagnosticsShort-circuit Protection Over-Current protectionIncorrect Connection Protection Output AC AlarmFuses and Grounding Maintenance To Clear an Alarm4Replacing the Fan Filters Monitoring Web-enabled User Interface Initial SetupInitial Setup Ethernet Interface PCBHow to Setup For the First Time Hardware SetupSetting Default Value Ethernet Setup1Default Settings SettingValue Resetting2User Configured Settings Removing Unit’s Top Cover 3Reset SettingsSetting Reset Value Ethernet Reset Jumper Operating Instructions Network Connection5Network Setup Using Dhcp What Power On DoesPassword 6Password Confirmation BoxesAutomatic Power-On Email How to Use the Web InterfaceManage Object DescriptionSetup 8Setup Page of Web Interface5Setup Page of Web Interface Monitor 9Monitor Page of Web Interface6Monitor Page of Web Interface Shutdown Code Code Fault DescriptionAutomatic Shutdown Email TM-DIOP-01XN-01 Troubleshooting Unusual or Erratic Operation User DiagnosticsEmergency Shutdown Symptom Check Diagnostic Guide 1Inverter Diagnostics 2Ethernet Diagnostics Specifications Inverter Specifications Electrical SpecificationsInverter Specifications Environmental Specifications Regulatory ApprovalsMechanical Specifications Inverter and Rack Mount Frame Dimensions Figure A-1Ethernet Specifications Page Warranty and Product Information WarrantyDisclaimer ProductReturn Material Authorization Policy ExclusionsInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc