Xantrex Technology XDI2048 manual Diagnostic Guide, 1Inverter Diagnostics, Symptom Check

Page 77

User Diagnostics

Diagnostic Guide

I

Table 5-1Inverter Diagnostics

Symptom

Check

Further Checks and Corrections

No output.

Is input breaker and power to rack

Check for availability of power

No front panel indication.

enabled?

source.

 

Is unit fully recessed and secured in

See Chapter 2.

 

rack?

 

 

Is power switch ON?

Beyond scope of user

 

 

troubleshooting. Service

 

 

required.

Red LED on.

Is input voltage within working

Verify input voltage is within

No output

range?

- 35 V to - 75 V

 

Are fans operating continuously at

Check if ambient temperature is

 

high speed?

within

 

 

0 – 50°C.

 

Internal module fault.

Beyond scope of user

 

 

troubleshooting. Service

 

 

required.

Unit cycles on/off.

Check for load fault.

Green LED - steady blink

 

briefly each time prior to

 

turning on.

 

Ensure no overload or short circuit condition is present at output.

 

Internal module fault?

Beyond scope of user

 

 

troubleshooting. Service

 

 

required.

No output.

Unit in shut down?

Check status of signal on

Green LED - short blink at

 

shutdown pin on user port or

a slow rate (approx. 1/

 

query same status using Ethernet

sec.)

 

if equipped with one.

 

Is unit fully recessed and secured in

If connectors don’t make full

 

rack?

contact, the unit remains

 

 

shutdown. See Chapter 2.

 

Internal module fault.

Beyond scope of user

 

 

troubleshooting. Service

 

 

required.

TM-DIOP-01XN-01

5-3

Image 77
Contents XDI2048 2kVA/1.5kW Page Xantrex Datacom Inverter Date and Revision Scope PurposeAudience OrganizationRelated Information Conventions UsedImportant Safety Instructions Page Contents Inverter Module Installation and Operation Remote Communication & Monitoring TroubleshootingWarranty and Product Information SpecificationsFigures Xii Tables Xiv Introduction Description Features and OptionsInverter Information Ethernet Information Features and FunctionsXDI2048HV-RM Part Number and Ordering InformationAssembly Packing List Initial Inspection2Shipping or Storage Carton Label Packaging for Shipping or StorageRack Mount Frame Rear View IntroductionLocation, Mounting and Ventilation Installation Into Cabinet Style Equipment RacksInstalling into Relay Racks Installation into Relay RacksDC Input Wire Connection DC Input PowerInput Connector and Cables Connecting the Input Wires AC Output Connector AC Load and Signal Line ConnectionLoad Wiring AC Output Voltage WireLoad Connection Overview User Line ConnectionUser Line Wiring User Line ConnectorUser Line Connection User Line ConnectionCAN/SYNC Connection CAN/SYNC ConnectorSpecifications Terminals Function CAN/SYNC WiringCAN/SYNC Pin-out Stand-Alone Operation Connection SchemesParallel Operation ConnectionParallel Operation Load Terminal Voltage Split Phase OperationSplit-Phase Operation 33-Phase Configurations Three Phase OperationWiring Output Configuration Terminals Model Voltage103-Phase Sync Connection Phase Synchronization and Signal WiringPhase, 3-Wire Y-Connection Output Wiring Phase, 3-Wire Delta Output WiringEthernet Port Phase, 4-Wire Y-Connection Output WiringPage Operation Installation into Rack Mount Frame 2Inverter Front Panel Installing an Inverter into a RackSystem Startup Operation of Inverter ModuleTheory of Operation Cooling Fans Standby ModeUser Interface 2User Line PinsFront Panel User LinesOverview Protections and AlarmsInput Voltage Protection Output Voltage Protection3Overload curve Overload ProtectionInternal Diagnostics Over Temperature Protection OTPShort-circuit Protection Over-Current protectionIncorrect Connection Protection Output AC AlarmFuses and Grounding To Clear an Alarm Maintenance4Replacing the Fan Filters Monitoring Initial Setup Web-enabled User InterfaceEthernet Interface PCB Initial SetupHardware Setup How to Setup For the First TimeSetting Default Value Ethernet Setup1Default Settings SettingValue Resetting2User Configured Settings Removing Unit’s Top Cover 3Reset SettingsSetting Reset Value Ethernet Reset Jumper Network Connection Operating Instructions5Network Setup What Power On Does Using Dhcp6Password Confirmation Boxes PasswordHow to Use the Web Interface Automatic Power-On EmailObject Description Manage8Setup Page of Web Interface Setup5Setup Page of Web Interface 9Monitor Page of Web Interface Monitor6Monitor Page of Web Interface Shutdown Code Code Fault DescriptionAutomatic Shutdown Email TM-DIOP-01XN-01 Troubleshooting Unusual or Erratic Operation User DiagnosticsEmergency Shutdown Symptom Check Diagnostic Guide1Inverter Diagnostics 2Ethernet Diagnostics Specifications Electrical Specifications Inverter SpecificationsInverter Specifications Regulatory Approvals Environmental SpecificationsMechanical Specifications Figure A-1 Inverter and Rack Mount Frame DimensionsEthernet Specifications Page Warranty Warranty and Product InformationProduct DisclaimerExclusions Return Material Authorization PolicyInformation About Your System Return ProcedureOut of Warranty Service Page Xantrex Technology Inc