Mounting the Remote (Step 3)

The remote can be permanently installed in a wall or cabinet.

The unit can also be flush-mounted into a rectangular opening in a wall or surface-mounted using a double-gang, non-metallic outlet box.

To flush mount the remote, an opening must be cut in the backing material to allow room for the circuit board, wires, and connectors. Allow at least 1 ½ inch minimum clearance behind the circuit board for the connectors and wires.

Important: Use great care when cutting out the area for the circuit board from the backing material (i.e., wallboard). Ensure there is enough area left to securely hold the screws.

Minimum Clearance

Ports

Circuit Board

Faceplate

1.5" (38 mm)

Figure 8 Minimum Clearance for the Remote

14

975-0123-01-01 Rev A

Image 20
Contents Series Meter Display Page Series Meter Display Date and Revision Contents Page Introduction Faceplate and RemoteImportant Safety Information Additional Safety Guidelines Features Faceplate and Remote FeaturesLiquid Crystal Display LCD Information Type Display Value/RangeAmp-Hour Reset and Backlight Button LED Status IndicatorInstallation See Jumper Installation on page 8 for instructionsJumper Installation Step To select and set the voltageJumper Locations on the FacePlate and Remote Cable Installation Step To connect the Faceplate to the C-Series controllerConnecting the Faceplate To connect the remote Connecting the Remote Mounting the Remote Step Minimum Clearance for the Remote16 116 mm To Mount the Remote Status Indicator OperationTurning the Display Backlight On or Off TroubleshootingResetting the Amp-Hour Meter Warranty and Return WarrantyTelephone Rev a Disclaimer ProductExclusions Return Material Authorization Policy Return Procedure Out of Warranty Service Other Xantrex ProductsPage Xantrex Technology Inc