Fujitsu PRN608-S user manual Serial Input/Output

Page 11

PRN608-S

i.0 (Default)

ii.1

iii.2

iv.3

v.4

vi.5

vii.6

viii.7

ix.8

x.9

r. Burn strobe light

i.-1

ii.-2

iii.-3

iv.-4

v.-5

vi.-6

vii.-7

viii.-8

ix.-9

Settings will be effective upon turn off and on.

*FTP628MCL00x/30x must be set as 384 dots.

*FTP6x8MCL05x/1xx and FTP6x8MCL35x is auto detected.

2.6Serial Input/Output

If BUSY control is selected:

When 236 bytes of data have been stored in the input buffer, the SBUSY signal becomes high to request that the computer temporarily stop sending data. When the amount of data stored in the input buffer becomes 235 bytes or less, the SBUSY signal changes to low to request that the host device continue data transfer. Up to 16 bytes of input data are guaranteed after the SBUSY signal has become high. When an error occurs, the SBUSY signal becomes high. Data input is prohibited until the error is cancelled.

If Xon/Xoff control is selected:

When 188 bytes of data has been stored in the input buffer, Xoff (1316) is output through the TxD terminal to request that the host device temporarily stops sending data. When the amount of data stored in the input buffer becomes 124 bytes or less, Xon (1116) is output to request that the computer continues data transfer. Up to 64 bytes of the input data are guaranteed after

Xoff has been output. When an error occurs, the Xoff signal is output to prohibit the data input.

28-03-2003 Page 2-11 of 53

Image 11
Contents For Fujitsu Thermal Printers FTP608 Series Copyright 1999-2003 by I/F-COM A/S All rights reserved Safety Precautions1-3 System Description Installation Maintenance APS Compatible Command SET Optional Labels InstallationFTP-628MCLxxx FTP-638MCLxxx Unpacking Settings Power supply2-9 2-10 Serial Input/Output 2-12 Thermal Head Control 2-14 2-15 Specifications Irda communication General Serial communicationUSB communication Auto form feed Firmware upgradeCharacter design 3-20 I/F-COM simple command set Ascii Ascii ENQAscii ACK Ascii BELAscii DC1 Ascii DLEAscii NAK Ascii DC2Ascii DC3 Ascii DC4Ascii SUB Ascii ETBAscii Can Ascii ESC Z PRN608-S Stop sending automatic status Name Format Change dot size Name Format PRN608-S Feed Paper Name Format EAN8 UpcaEAN13 ‘d’ Space Black Mark Name Set black mark parameters Format D1,d2,..,dX Escape Sequences Ascii Function Request analogue voltage Store/Transport Daily useEMC & ESC Electrical DataMechanical Data Environmental DataTemperature Test Pin Function LED1+ LED2+ INPUT1 INPUT2 GND PinCUT GND LED USB USB+ GND DTR GND DSRCTS RTSOFF Seiko compatible command set optionalESC Fujitsu compatible command set optionalESC RS ESC US7-46 7-47 GS E APS compatible command set optionalESC S BIT Function BIT = 0 BIT = ESC L ESC/POS compatible command set optionalESC FF 7-51 Bottom view Optional sensor description Top viewRED White Black