Fujitsu PRN608-S user manual General Serial communication, USB communication, Irda communication

Page 17

PRN608-S

3Function

3.1General

Notice, when data is sent from the external equipment to the printer controller, all data has to be sent as binary file. If data is being sent as a character file, and some data in the file is equal to EOF, the rest will not be received.

3.2Serial communication.

Standard communication is; Baud rate; 115.200 Baud Data bits = 8

Stop bits = 1. Parity = None

Flow control = Hardware handshake

Baud rate can be changed by a software command or by entering setting mode..

3.3USB communication.

Build in USB interface is 100% compliant to USB 1.1 and fully approved by the USB organisation. For more details please contact I/F-COM.

By plug USB cable - Host system will recognise I/F-COM interface board.

Before connecting USB cable please set USB port as offline. Interface board will automatically online USB port. Data cannot be send from interface board to host. USB is not a bi-directional communication.

3.4IRDA communication.

PRN608-S is prepared for IRDA via connector for IRDA transmission. Please contact I/F-COM for more information.

28-03-2003 Page 3-17 of 53

Image 17
Contents For Fujitsu Thermal Printers FTP608 Series Copyright 1999-2003 by I/F-COM A/S All rights reserved Safety Precautions1-3 System Description Installation Maintenance APS Compatible Command SET Optional FTP-628MCLxxx FTP-638MCLxxx InstallationUnpacking LabelsSettings Power supply2-9 2-10 Serial Input/Output 2-12 Thermal Head Control 2-14 2-15 Specifications Irda communication General Serial communicationUSB communication Auto form feed Firmware upgradeCharacter design 3-20 I/F-COM simple command set Ascii ACK Ascii ENQAscii BEL AsciiAscii DC1 Ascii DLEAscii DC3 Ascii DC2Ascii DC4 Ascii NAKAscii SUB Ascii ETBAscii Can Ascii ESC Z PRN608-S Stop sending automatic status Name Format Change dot size Name Format PRN608-S Feed Paper Name Format EAN8 UpcaEAN13 ‘d’ Space Black Mark Name Set black mark parameters Format D1,d2,..,dX Escape Sequences Ascii Function Request analogue voltage Store/Transport Daily useMechanical Data Electrical DataEnvironmental Data EMC & ESCTemperature Test Pin Function LED1+ LED2+ INPUT1 INPUT2 GND PinCUT GND LED USB USB+ GND CTS DSRRTS DTR GNDOFF Seiko compatible command set optionalESC RS Fujitsu compatible command set optionalESC US ESC7-46 7-47 GS E APS compatible command set optionalESC S BIT Function BIT = 0 BIT = ESC L ESC/POS compatible command set optionalESC FF 7-51 Bottom view Optional sensor description Top viewRED White Black