7.2 Sense Data Analysis
7.2Sense Data Analysis
7.2.1Error information indicated with sense data
Subsection 7.2.2 onwards explain troubleshooting using sense data. For details of the following sense data, refer to Chapter 5 “Sense Data Error Recovery Methods” of the Interface Specifications.
Table 7.1 lists the definition of sense data. For details of sense data, refer to the Interface Specifications.
|
| Table 7.1 | Definition of sense data | |
|
|
|
|
|
| Sense data |
|
|
|
|
|
|
|
|
Sense | Additional | Additional |
| Definition |
sense code |
|
| ||
key | sense code |
|
| |
qualifier |
|
| ||
|
|
|
| |
|
|
|
| |
3 | 0C | 03 | A write to a disk terminated abnormally. | |
|
|
|
| |
4 | 32 | 01 | Failed to update the defect list (due to unrecoverable error during | |
|
|
| write, verify error after write.). | |
| 40 | xx | An error occurred in | |
| C4 | xx | A drive error occurred. | |
|
|
|
| |
1 | 1x | xx | A disk read error occurred. | |
3 | 1x | xx | A disk read error occurred. | |
|
|
|
| |
E | 1D | 00 | Data discrepancy found by VERIFY command byte check. | |
|
|
|
| |
5 | 2x | xx | A SCSI error, such as an invalid operation code, occurred. | |
4 or B | 44 | xx | A hardware error occurred inside HDDs. | |
B | 47 | xx | An interface error occurred. | |
| 4B | xx | An interface error occurred. | |
| 4E | 00 | An overlap command was issued. | |
|
|
|
|
|