1.3Functionality and Features

1.3.1Functional Description

This product is a new class of Gigabit Ethernet (GbE) converged network interface controller (C- NIC) that can simultaneously perform accelerated data networking, storage networking, and high- performance clustering on a standard Ethernet network. The C-NIC offers acceleration for all popular protocols used in the data center, such as:

• TCP Offload Engine (TOE) for accelerating TCP

`Offloading technologies are supported when this product is installed in a system with Windows Server 2003 with Scalable Networking Pack (SNP).

Using the Broadcom teaming software, you can split your network into virtual LANs (VLANs) as well as group multiple network adapters together into teams to provide network load balancing and fault tolerance functionality. For details about teaming, refer to " Broadcom Advanced Server Program (BSAP) Overview" (Jpg.109) in "1.3.3 Teaming Function" (Jpg.109). For a description of VLANs, refer to "1.3.4 Virtual LAN Function" (Jpg.112). For instructions on configuring teaming and creating VLANs on Windows operating systems, refer to "1.3.3 Teaming Function" (Jpg.109).

1.3.2Features

The following is a list of this product features:

TCP Offload Engine (TOE)

Single-chip solution

-Standard Ethernet frame size (1518 bytes)

-PCI Express v1.0A, x4

-Full fast-path TCP offload

-Zero copy capable hardware

Other performance features

-TCP, IP, UDP checksum

-TCP segmentation

Manageability

-Broadcom Advanced Control Suite2 (BACS2) diagnostic and configuration software suite

-Supports PXE 2.0 specification

-Statistics for SNMP MIB II, Ethernet-like MIB, and Ethernet MIB (IEEE Std 802.3z, Clause 30)

-IPMI support

Advanced network features

-Jumbo frames (up to 9 KB)

-Virtual LANs

-Flow Control (IEEE Std 802.3x)

-LiveLink™ (supported in both the 32-bit and 64-bit Windows operating systems)

-Logical Link Control (IEEE Std 802.2)

Layer-2 Priority Encoding (IEEE 802.1p)

E

1 1 Gbit/s Ethernet I/O Module 107

Image 7
Contents 101 Before Reading This ManualCD-ROM drive\Setup.exe SymbolsEntering commands Keys Symbols Definition103 AbbreviationsProduct names Expressions and abbreviations Recycle Handling this product104 Contents Overview Specifications106 Features Functionality and FeaturesFunctional Description Broadcom Advanced Control Suite 2 BACS2 TCP Offload Engine TOE108 Types of Teams Load Balancing and Fault ToleranceTeaming Function Broadcom Advanced Server Program Bsap Overview110 Smart Load Balancing and FailoverLink Aggregation 802.3ad Generic Trunking FEC/GEC/802.3ad-Draft StaticWindows Server With SNP SLB Auto-Fallback DisableVlan Overview Virtual LAN FunctionLiveLink Teaming and Large Send Offload/Checksum Offload SupportComponent Description PC #3 PC #5. Tagging is not enabled on PC #3 switch portAdding VLANs to Teams 114Installing a 1Gbit/s Ethernet I/O Module 116 Installing in a Server BladeInstallation Position of the 1Gbit/s Ethernet I/O Module Installation Procedure for the 1Gbit/s Ethernet I/O ModuleSecure the 1Gbit/s Ethernet I/O Module with the screws Install the 1Gbit/s Ethernet I/O ModuleInstall the server blade to the chassis Remove the top coverInstalling the LAN Drivers Installing the Driver SoftwareClick Next Glossary Broadcom Gigabit Ethernet Overview120 Teaming and Network Addresses Teaming ConceptsTeaming and Network Addresses Network Addressing122 Types of TeamsBroadcom Gigabit Ethernet Teaming Services 124 Link Aggregation Ieee 802.3ad LacpGeneric Trunking Software ComponentsSoftware Broadcom Name Windows File Name Component Hardware Requirements126 Broadcom Teaming Software ComponentSupported Features by Team Type Configuring Teaming128 Process for Selecting a Team Type Selecting a Team TypeYes Intermediate Driver Teaming MechanismsArchitecture 130Inbound Traffic Flow SLB Only Outbound Traffic Flow132 Protocol SupportOr the streams may look like this Types of Teams Switch-IndependentPerformance Generic Static Trunking Switch-Dependent134 Dynamic Trunking Ieee 802.3ad Link Aggregation 136 Feature AttributeOutgoing packet management 100 Incoming/outgoing Same speed Speeds Supported for Each Type of TeamType of Team Link Speed Traffic Direction Speed Support 10/100/1000 Incoming/outgoing Mixed speedAdapter Properties Supported by Teaming Virtual Adapter Wake on LAN Preboot Execution environment PXETeaming and Other Advanced Networking Properties 138Jumbo Frames Checksum OffloadIeee 802.1p QoS Tagging Large Send OffloadGeneral Network Considerations Teaming Across SwitchesSwitch-Link Fault Tolerance Preboot Execution EnvironmentRed ARP TableBlue 100=49C9 SLB Team 102=5ECA 8283142 Spanning Tree Algorithm 144 Topology Change Notice TCNPort Fast/Edge Port Layer 3 Routing/SwitchingTeaming with Hubs for troubleshooting purposes only Hub Usage in Teaming Network ConfigurationsTeaming with Microsoft NLB/WLBS SLB TeamsSLB Team Connected to a Single Hub Generic and Dynamic Trunking FEC/GEC/IEEE 802.3adTeaming Configuration Tips Troubleshooting Teaming ProblemsQuestion Answer Troubleshooting GuidelinesFrequently Asked Questions 148Adapter Be configured on the same server? ServerIs restored fallback? It must be upgraded using the Setup installer150 Message Cause Corrective Action Number Event Log MessagesWindows System Event Log messages Base Driver Physical Adapter/MiniportReboot the operating Duplex settings Medium not supported152 Unable to register with Driver cannot Unload any Ndis Intermediate Driver Virtual Adapter/TeamUnspecified failure during Intermediate Driver Event Log MessagesSystem on which it is Support the operating Release notes and installSuccessfully enabled a Only Interface 154Message Cause Corrective Action Number 156 BACS2 OverviewThird pane contains the Menu bar Only available with this product J5.4.8 Licensespg.175 Types of Information Provided by BACS2Function Details Licenses158 Installing the BACS2For Windows Server 2003 Installer starts upLicense agreement window appears 160 Custom Set up window appearsFor Windows Server 2003, Windows 2000 Server CD-ROM drive \PROGRAMS\GENERAL\Broadcom\MgmtApps\setup.exe162 Setting of BACS2Starting BACS2 Vital SignFollowing network status information is provided Network StatusWith headers appended to them By the host CPU164 Team StatusRange from 2 to Memory Address ResourcesFollowing information can be checked on the Resources tab Function number for the second port is Interrupt Request166 HardwareFollowing information can be checked on the Hardware tab 802.1p QOS Not enable QoS. Otherwise, problems may occurAdvanced Following information can be checked on the Advanced tab168 Sets the speed at 10 Mbit/s and the mode to Full-Duplex Locally AdministeredNot Present default Administered address include the followingNetwork Test Diagnostics170 Identifying the adapter Control RegistersGeneral Statistics Statistics172 Ieee 802.3 Statistics 174 Command Length = MAC Rx w/ PauseCommand Custom StatisticsLicenses 176 Configuring TeamingCreating and Modifying a Team Using the Teaming Wizard Using the Broadcom Teaming WizardOn the BACS2 Tools menu, click Create a Team 178 Broadcom Advanced Control Suite 2 BACS2 Select the standby member from the list of adapters Broadcom Advanced Control Suite 2 BACS2 Type the Vlan name and then click Next 182 To tag the VLAN, click Tagged and then click Next Value must be between 1 Type the Vlan tag value and then click NextClick Yes to add another Vlan and then click Next 184Click Finish to commit the changes Click the BACS2 Tools menu → Create a Team Using Expert ModeTo work without the wizard, click Expert Mode Creating a TeamBroadcom Advanced Control Suite 2 BACS2 Modifying a Team Configure the team IP address188 Adding a Vlan Following shows how to modify a teamWizard Welcome screen appears Type the Vlan ID and Vlan name, and click Apply Viewing Vlan Properties and Running Vlan TestsDeleting a Vlan Click the Tools menu → Configure a TeamClick Remove Vlan Click Apply 192 Following shows how to configure a LiveLinkRepeat for each of the other listed team members Click Apply Configuring LiveLink in VLAN-tagged EnvironmentsViewing the Team Properties and Statistics Saving and Restoring a ConfigurationFollowing shows how to save a configuration Following shows how to restore a configurationAppendix a Contact 196 Primergy