Table 6.1 Check items (continued)
Problem | Possible cause | Response |
|
|
|
The check | The carrier fixing bracket | Remove the carrier fixing bracket as |
indicator is on. | was not removed. | explained in Section 3.2, “Removing the |
|
| Carrier Fixing Bracket.” |
|
|
|
| Turn the power off then on again. If the | |
|
| check indicator turns on again, contact the |
|
| sales person in charge or a Fujitsu service |
|
| representative.* |
|
|
|
“Check” lamp | The pick roller is dirty. | When the power is turned off, the mes- |
blinks at 4 |
| sage is cleared. |
seconds period. |
| Even if the message is displayed, the read |
|
| operation can be continued. Clean the |
|
| pick roller after the read operation. |
|
| (See Section 5.3.2.) |
|
|
|
| The unallowable document | If a document not meeting the scanner |
| was read in the automatic | specifications is read in the automatic |
| document feeder. | document feeder, the document is not fed |
| (See Section 4.3.) | smoothly and an error message may be |
|
| displayed. |
|
| Read the document in the flat bed station. |
|
|
|
Paper double feed. | Pad is dirty. | Clean the Pad. (See Section 5.3.2) |
|
|
|
| Pad is worn out. | Replace the Pad. (See Section 5.4.2) |
|
|
|
Miss pick. | Pick roller is dirty. | Clean the Pick roller. (See Section 5.3.2) |
|
|
|
| Pick roller is worn out. | Replace the Pick roller. |
|
| (See Section 5.4.3) |
|
|
|
Paper jam. | Some foreign particles are in | Clean the ADF (See Section 5.3.2) or |
| ADF. | remove any foreign particles. |
|
|
|
*Please check the test mode in appendix B, if possible, before calling the service representa- tive and inform status of the indicators.