Chapter 3 Power Supply Installation
Power Supply Module Installation
Figure 3-8 Insert the Power Supply Module
207233
Step 4 Use a ratcheting torque screwdriver to torque each screw to
Wiring the Power Source
Before you wire the power source, review the warnings in this section:
Warning This product relies on the building’s installation for
AC: 5 A, DC: 15 A Statement 1005
Warning A readily accessible
Warning Only trained and qualified personnel should be allowed to install or replace this equipment. Statement 1030
Warning Hazardous voltage or energy may be present on power terminals. Always replace cover when terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in place. Statement 1086
Step 1 Locate the AC and DC circuit breakers, turn them OFF, and tape them in the OFF position.
Note Do not connect the switch to a power source that has an ON/OFF switch.
Step 2 Use a Phillips screwdriver to loosen the captive screw on the
Cisco CGS 2520 Hardware Installation Guide
|
| ||
|
|