ACIP Description
ACIP Interface
The ACIP’s ATM interface is full duplex. You must use the appropriate ATM interface cable to connect the ACIP with external ATM equipment. (Refer to the section “ACIP Cables, PLIM, and Connections,” on page 7, for descriptions of ATM cables and connectors.) The ACIP provides an interface to ATM switching fabrics for transmitting and receiving data at rates of up to 155 Mbps bidirectionally; the actual rate is determined by the PLIM. The ACIP supports a PLIM that connects to the following physical layer: SONET/SDH 155 Mbps, multimode fiber
SONET Distance Limitations
The SONET specification for
The typical maximum distances for multimode transmissions, as defined by SONET, are in Table 1. If the distance between two connected stations is greater than these maximum distances, significant signal loss can result, making transmission unreliable.
Table 1 SONET Maximum
Transceiver Type | Maximum Distance between Stations1 |
Multimode | Up to 1.5 miles (3 kilometers) |
|
|
1.Table 1 gives typical results. You should use the power budget calculations to determine the actual distances.
Power Budget
To design an efficient optical data link, evaluate the power budget. The power budget is the amount of light available to overcome attenuation in the optical link and to exceed the minimum power that the receiver requires to operate within its specifications. Proper operation of an optical data link depends on modulated light reaching the receiver with enough power to be correctly demodulated.
Attenuation, caused by the passive media components (cables, cable splices, and connectors), is common to both multimode and
The following variables reduce the power of the signal (light) transmitted to the receiver in multimode transmission:
•Chromatic dispersion (spreading of the signal in time because of the different speeds of light wavelengths)
•Modal dispersion (spreading of the signal in time because of the different propagation modes in the fiber)
Attenuation is significantly lower for optical fiber than for other media. For multimode transmission, chromatic and modal dispersion reduce the available power of the system by the combined dispersion penalty (dB). The power lost over the data link is the sum of the component, dispersion, and modal losses.
Table 2 lists the factors of attenuation and dispersion limit for typical
ATM Cable Interface Processor (ACIP) Installation and Configuration 5