Cisco Systems IGX 8400 manual BC-SR Connections and Status LEDs, Connection/Indicator Function

Page 43

Network Trunk Module

Figure 4-25 BC-SR Faceplate

BC-SR

RS 449/MIL188

X.21

V.35

LOS (red)

Bad Clk (red)

Yellow alarm (yellow)

DSR (green)

DTR (green)

RXD (green)

TXD (green)

Fail (red)

Active (green)

 

 

 

 

H8318

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-19

BC-SR Connections and Status LEDs

 

 

 

 

Connection/Indicator

Function

 

 

 

 

EIA/TIA-449 data connector

DB-37 female connector

 

 

 

 

X.21 data connector

DB-15 female connector

 

 

 

 

V.35 data connector

34-pin female MRAC connector

 

 

 

 

 

LOS light (red)

 

Loss of signal at the local end

 

 

 

 

Bad CLK light (red)

Loss of clock or clock out of range

 

 

 

 

Yellow alarm light (yellow)

Loss of packet alignment (NTM) or frame alignment at remote end

 

 

 

 

 

DSR light (green)

 

The DSR lead is high (ON)

 

 

 

 

 

DTR light (green)

 

The DTR lead is high (ON)

 

 

 

 

 

RXD light (green)

 

The receive data line shows activity

 

 

 

 

 

TXD light (green)

 

The transmit data line shows activity

 

 

 

 

 

Fail light (red)

 

An error occurred. First, reset the card with resetcd f. If the LED comes on

 

 

 

 

again, contact the Cisco TAC through Customer Engineering

 

 

 

 

Active: light (green)

The card is in service and has active circuits

 

 

 

 

 

Trunk Cards 4-43

Image 43
Contents Trunk Cards Trunk Front Cards Card Acronym Card Name Trunk Interface CardsTrunk Operating Modes Trunk Card MaintenanceLoopback Test Universal Switching Module Enhanced Introduction to the UXM-E Trunk ModeExample Networks with UXM-Es Determining the UXM-E’s Mode of OperationUXM-Es in a Network with Heterogeneous Traffic UXM-E Trunk FeaturesBack Cards for the UXM-E UXM-E InterfacesCard Name Card Description UXM-E Front Card UXM-E Status LEDs Fail Active Standby Status of Card Switchover to a Redundant UXM-EMaximum Number of UXM-Es Cabled UXM-E RedundancyCard Mismatch Cellbus Bandwidth UsageUXM-E as a Clock Source OC3 Planning for Cellbus Bandwidth AllocationATM Across a Public ATM Network Calculating Cellbus Bandwidth ChangesTraffic from FastPacket-Based Cards Traffic Type UXM-E in Trunk ModeRouting over Cell Trunks Only Types of Supported TrafficInverse Multiplexing over ATM on IGX Trunks Types of Connections on a UXM-E TrunkAdding an IGX Feeder Line Redundancy Adding and Removing IMA Group LinksGateway Type Routing Load Type IMA ProtocolTwo-Segment Connections Routing Feeder Connection Cell Endpoint a Endpoint B TypeABR.FST Gwtypenone Three-Segment ConnectionsFeeder Connection Cell Endpoint a Endpoint B Type RT-VBR GwtypenoneUXM-E Atfr Activation and Configuration of a UXM-E in Trunk ModeOC3 STM1 SMF 20Cisco IGX 8400 Series Reference IGX-UXM-E Alarms for Physical Lines and Logical TrunksSCR and PCR Policing at Less than 50 CPS on UXM-E BXM10 PCR Policing Application Example Trunk Statistics for TroubleshootingUXM-E Interface Cards Summary StatisticsConnector/Indicator Function Connectors and LEDs for SMF and MMF Back CardsOC-3/STM1 Back Cards 11 BC-UAI-4-155-SMF Faceplate 12 BC-UAI-2-155-SMF Faceplate T3 Back CardsConnectors/Indicator Function Connectors and LEDs for BC-UAI-6-T3 and BC-UAI-3-T3BC-UAI-6-T3 Faceplate 14 BC-UAI-3-T3 Faceplate E3 Back CardsBC-UAI-6-E3 Faceplate Connectors and LEDs for BC-UAI-6-E3 and BC-UAI-3-E316 BC-UAI-3-E3 Faceplate T1 Back CardsBC-UAI-8-T1-DB-15 Faceplate 18 BC-UAI-4-T1-DB-15 Faceplate E1 Back CardsBC-UAI-8-E1 DB-15 Faceplate Port 21 BC-UAI-4-E1 DB-15 Faceplate 22 BC-UAI-4-E1 BNC Faceplate NTM Status Cable Redundancy for the NTMNetwork Trunk Module BC-T1 Faceplate Description T1 Interface Card BC-T1BC-T1 Connections and Status LEDs 23 BC-T1 FaceplateE1 Interface Back Card BC-E1 RX-TX BC-E1 Connections and Status LEDsSubrate Interface Card BC-SR BC-SR Connections and Status LEDs Connection/Indicator FunctionY1 Interface Back Card BC-Y1 RX MON BC-Y1 Connections and Status LEDsTX MON 46Cisco IGX 8400 Series Reference