Cisco Systems IGX 8400 manual T3 Back Cards, BC-UAI-2-155-SMF Faceplate

Page 26

UXM-E Interface Cards

Figure 4-12 BC-UAI-2-155-SMF Faceplate

UAI-2-155

SMF

R LOC Y REM G OK

P

O

R

T

1

R LOC Y REM G OK

P

O

R

T

2

R X

T X

R X

T X

RLOC Y REM G OK

P

O

R

T

2

R X

T X

FAIL

ACTIVE

H11698

T3 Back Cards

The T3 back cards for the UXM-E are BC-UAI-6-T3 and BC-UAI-3-T3. These cards have six and three pairs of BNC connectors, respectively. Each port has a tri-color LED whose color indicates its status. Each card also has a red Fail LED and a green Active LED to indicate the status of the card. Table 4-13lists the connectors and LEDs. Figure 4-13show the six-port T3 card. Figure 4-14shows the three-port T3 card. For technical data on T3 lines, see the appendix “System Specifications.”

4-26Cisco IGX 8400 Series Reference

Image 26
Contents Trunk Cards Trunk Interface Cards Trunk Front Cards Card Acronym Card NameLoopback Test Trunk Card MaintenanceTrunk Operating Modes Introduction to the UXM-E Trunk Mode Universal Switching Module EnhancedDetermining the UXM-E’s Mode of Operation Example Networks with UXM-EsUXM-E Trunk Features UXM-Es in a Network with Heterogeneous TrafficCard Name Card Description UXM-E InterfacesBack Cards for the UXM-E UXM-E Front Card Cabled UXM-E Redundancy Switchover to a Redundant UXM-EMaximum Number of UXM-Es UXM-E Status LEDs Fail Active Standby Status of CardUXM-E as a Clock Source Cellbus Bandwidth UsageCard Mismatch Planning for Cellbus Bandwidth Allocation OC3Calculating Cellbus Bandwidth Changes ATM Across a Public ATM NetworkTypes of Supported Traffic UXM-E in Trunk ModeRouting over Cell Trunks Only Traffic from FastPacket-Based Cards Traffic TypeTypes of Connections on a UXM-E Trunk Inverse Multiplexing over ATM on IGX TrunksAdding an IGX Feeder Adding and Removing IMA Group Links Line RedundancyRouting Feeder Connection Cell Endpoint a Endpoint B Type IMA ProtocolTwo-Segment Connections Gateway Type Routing Load TypeRT-VBR Gwtypenone Three-Segment ConnectionsFeeder Connection Cell Endpoint a Endpoint B Type ABR.FST GwtypenoneOC3 STM1 SMF Activation and Configuration of a UXM-E in Trunk ModeUXM-E Atfr 20Cisco IGX 8400 Series Reference BXM Alarms for Physical Lines and Logical TrunksSCR and PCR Policing at Less than 50 CPS on UXM-E IGX-UXM-ETrunk Statistics for Troubleshooting 10 PCR Policing Application Example Summary Statistics UXM-E Interface CardsOC-3/STM1 Back Cards Connectors and LEDs for SMF and MMF Back CardsConnector/Indicator Function 11 BC-UAI-4-155-SMF Faceplate T3 Back Cards 12 BC-UAI-2-155-SMF FaceplateBC-UAI-6-T3 Faceplate Connectors and LEDs for BC-UAI-6-T3 and BC-UAI-3-T3Connectors/Indicator Function E3 Back Cards 14 BC-UAI-3-T3 FaceplateConnectors and LEDs for BC-UAI-6-E3 and BC-UAI-3-E3 BC-UAI-6-E3 FaceplateT1 Back Cards 16 BC-UAI-3-E3 FaceplateBC-UAI-8-T1-DB-15 Faceplate E1 Back Cards 18 BC-UAI-4-T1-DB-15 FaceplateBC-UAI-8-E1 DB-15 Faceplate Port 21 BC-UAI-4-E1 DB-15 Faceplate 22 BC-UAI-4-E1 BNC Faceplate Network Trunk Module Cable Redundancy for the NTMNTM Status T1 Interface Card BC-T1 BC-T1 Faceplate Description23 BC-T1 Faceplate BC-T1 Connections and Status LEDsE1 Interface Back Card BC-E1 BC-E1 Connections and Status LEDs RX-TXSubrate Interface Card BC-SR Connection/Indicator Function BC-SR Connections and Status LEDsY1 Interface Back Card BC-Y1 TX MON BC-Y1 Connections and Status LEDsRX MON 46Cisco IGX 8400 Series Reference