Chapter 1 Overview
Power Options and Requirements
Power Options and Requirements
This section includes the following information:
•Power Options
•Current Draw Requirements
•Installing Surge Suppressors on Output Device Connections
•Connect Reader Devices with Module Power Off
Power Options
Table
•The DC power connections on each module are Voltage In (VIN) and Ground (GND).
•For information on configuring PoE, see the documentation for your network switch. Your switch must support PoE and be properly configured to use this feature with the Cisco Physical Access Gateway.
Table | Power Options for the Cisco Physical Access Control Modules | ||
|
|
|
|
Module |
| Power over Ethernet (PoE) | 12 through 24V DC |
|
|
| |
Cisco Physical Access Gateway | Supported | Supported | |
|
|
| |
Cisco Reader Module | Not Supported | Supported | |
|
|
| |
Cisco Input Module | Not Supported | Supported | |
|
|
| |
Cisco Output Module | Not Supported | Supported | |
|
|
|
|
Current Draw Requirements
Each Cisco Physical Access Control module requires a minimum amount of available power, as described in Table
|
|
|
| Table | Current Draw Requirements for the Cisco Physical Access Control Modules | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Current Draw |
|
|
|
|
|
| Module |
| Requirement | Notes | |
|
|
|
|
|
|
| ||
|
|
|
| Cisco Physical Access Gateway | 1.5A | 1.5A is required for the Gateway module only. | ||
|
|
|
|
|
|
| Add an additional 1A if a reader or lock is | |
|
|
|
|
|
|
| attached to the module. | |
|
|
|
|
|
|
| ||
|
|
|
| Cisco Reader Module | 1A | 1A is required for the Reader module only. Add | ||
|
|
|
|
|
|
| an additional 1A if a reader or lock is attached to | |
|
|
|
|
|
|
| the module. | |
|
|
|
|
|
|
| ||
|
|
|
| Cisco Input Module | 1A | N/A | ||
|
|
|
|
|
|
| ||
|
|
|
| Cisco Output Module | 1A | N/A | ||
|
|
|
|
|
|
|
| |
|
|