Cisco Systems OL-20932-02 manual Module Features, 30VDC

Page 14

Chapter 1 Overview

Optional Expansion Modules

Module Features

Figure 1-4shows the modules for a Cisco Physical Access Control system.

Figure 1-4 Cisco Physical Access Gateway and the Optional Modules

Cisco Physical

Reader

Input

Output

Access Gateway

Module

Module

Module

187057

Gateway

Cisco Reader Module

Cisco Input Module

Cisco Output Module

 

 

 

 

 

 

 

 

Mandatory module.

Requires connection to

Requires connection to

Requires connection to

Connects up to two doors

 

an Access Gateway using

 

an Access Gateway using

 

an Access Gateway using

 

a three-wire CAN bus.

 

a three-wire CAN bus.

 

a three-wire CAN bus.

 

using the 10 pin Wiegand

 

 

 

 

 

 

 

 

 

 

 

reader port, which can be

Connects up to two doors

10 supervised input ports

8 output ports: Form C

 

configured as two

 

using the 10 pin Wiegand

Example inputs are: Push

 

contacts rated at 5A

 

five-pin ports.

 

reader port, which can be

 

30VDC

 

 

 

button switches, Glass

 

 

 

 

configured as two 5 pin

 

 

 

Connects up to 15

 

 

Break sensors, or any

Example outputs are:

 

ports.

 

 

optional expansion

 

 

contact closure input.

 

lights, LEDs, or any

 

 

 

 

 

 

modules using a

Power: 12 through 24V

 

circuit

 

contact closure output

 

three-wire CAN bus.1

 

DC

Power: 12 through 24V

 

circuit.

 

 

 

 

 

 

Power-over-Ethernet

Three output ports: Form

 

DC

Power: 12 through 24V

 

(POE) or 12 through 24V

 

C contacts rated at 5A

Tamper & Power Fail

 

DC

 

DC

 

30VDC

 

 

 

 

 

inputs (can be configured

Tamper & Power Fail

 

 

 

 

 

Two Ethernet ports

Three supervised input

 

as additional

 

inputs (can be configured

Three output ports:

 

ports

 

unsupervised ports)

 

as additional

 

 

 

 

 

unsupervised ports)

 

Form C contacts rated at

Tamper & Power Fail

 

 

 

 

 

 

 

 

 

5A 30VDC

 

inputs (can be configured

 

 

 

 

Three supervised input

 

as additional

 

 

 

 

 

unsupervised inputs)

 

 

 

 

 

ports2

 

 

 

 

 

Tamper & Power Fail

One RS-485 serial port

 

 

 

 

 

(not supported in this

 

 

 

 

 

inputs (can be configured

 

 

 

 

 

 

 

release).

 

 

 

 

 

as additional

 

 

 

 

 

 

 

 

 

 

 

 

 

unsupervised inputs)

 

 

 

 

 

 

One RS-485 serial port

 

 

 

 

 

 

 

(not supported in this

 

 

 

 

 

 

 

release).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.The modules are connected using the CAN1 interface. The CAN2 interface is not supported in this release.

2.A supervised input supports four states: normal, alarm, open and short. An unsupervised input only indicates normal or alarm.

Cisco Physical Access Gateway User Guide

1-6

OL-20932-02

 

 

Image 14
Contents Cisco Physical Access Gateway User Guide Americas HeadquartersCisco Physical Access Gateway User Guide N T E N T S Safety Warnings Environmental Specifications A-1 Contents Cisco Physical Access Gateway User Guide Safety Warnings PrefaceViii Overview System Overview Cisco Physical Access GatewayFeature Benefit Support for Multiple Cisco Physical Access Gateways Related DocumentationCisco Physical Access Manager Optional Expansion Modules Module Features 30VDCCan Bus Connections for Optional Modules Installation and Configuration Summary Door Device Wiring Requirements Typical Wire Function Wires Gauge Type UseUnderstanding Supervised and Unsupervised Input Devices Example of a Supervised Door Sensor Module Power over Ethernet PoE Through 24V DC Power Options and RequirementsPower Options Current Draw RequirementsInstalling Surge Suppressors on Output Device Connections Connect Reader Devices with Module Power OffMounting a Gateway or Optional Module Wall Mounting a Gateway or Optional ModuleWall Mount Installation Kit Contents OL-20932-02 Contents Cisco Physical Access Gateway OverviewPackage Contents Physical Overview and Port DescriptionCisco Physical Access Gateway Ports and Connectors Top View Description LED StatusStatus Status Description Input Port LEDsBefore You Begin Installing the Cisco Physical Access GatewayProcedure Power Connections for the Cisco Physical Access Gateway Label Description Wire Connection Chassis One Reader First Reader in aHcrd 271592 271593 CAN+ 271591 Understanding Network Time Protocol NTP Settings Connecting a PC to the Gateway Entering the Gateway Network Settings 12 Login Screen for the Cisco Physical Access Gateway13 Network Settings for the Cisco Physical Access Gateway Changing the User Password Enter the Current Password Enter the New PasswordUpgrading the Gateway Firmware Using a Direct Connection 15 Image Management for the Cisco Physical Access GatewayOption 1 Local Disk Option 2 Remote Tftp ServerDisplaying Serial Numbers and Other Information Installing and Configuring the Cisco Physical Access Gateway Hard Reset Restore Factory Defaults Resetting the Cisco Physical Access GatewaySoft Reset Powercycle Connecting a Cisco Reader Module Door Related Hardware Cisco Reader Module Ports and Connectors Cisco Reader Module Ports and Connectors Top View Cisco Physical Access Gateway User Guide OL-20932-02 Installing the Cisco Reader Module Status LEDsPower Connection for the Cisco Reader Module 271600 +12v PWR red Output RED brown GRN orange 271592 271593 Connecting a Cisco Input Module Can connection Additional Connector plugs Cisco Input Module Ports and Connectors Top View Installing the Cisco Input Module Power Connections for the Input and Output Modules Can Connections Input and Output Modules 1K,, 1% Connecting a Cisco Output Module Connecting a Cisco Output Module Package Contents Cisco Output Module Ports and Connectors Cisco Output Module Ports and Connectors Top View Output Module LEDs Installing the Cisco Output Module Power Connections for the Cisco Output Module CAN+ Cisco Physical Access Gateway User Guide OL-20932-02 OL-20932-02 Safety Warnings Statement 1071-Warning DefinitionWarnung Wichtige Sicherheitshinweise Avvertenza Importanti Istruzioni Sulla SicurezzaAviso Instruções Importantes DE Segurança Guarde Estas InstruçõesGEM Disse Anvisninger Page Statement 369-Power over Ethernet PoE Ieee 802.3af Statement 353-This Product Must be Connected Appendix 6 Safety Warnings Statement 1040-Product Disposal Statement 1004-Installation Instructions Cisco Physical Access Gateway User Guide OL-20932-02 Environmental Specifications GatewayEnvironmental Specifications for the Cisco Reader Module Environmental Specifications for the Cisco Input ModuleEnvironmental Specifications for the Cisco Output Module OL-20932-02