Cisco Systems A03D600GA2 manual Available PCIe RAID Controller Options, Super Capacitor Option

Page 25

 

CONFIGURING the SERVER

 

 

 

Table 8 Available PCIe RAID Controller Options (continued)

 

 

 

Product ID (PID)

PID Description

 

 

 

UCS-RAID-9285CV-E or

LSI MegaRAID SAS 9285CV-8e or 9286CV-8e (RAID 0, 1, 5, 6, 10)

UCS-RAID9286CV-8E

Supports from one to eight external SAS ports (up to 240 external drives).

 

 

 

 

NOTE: For SAS 9285CV-8e or 9286CV-8e external drive enclosure

 

support, see the compatibility list (enclosure section) at the following

 

link:

 

http://tinyurl.com/b4etshk

 

Cisco is able to support customers with questions related to the SAS

 

9285CV-8e or 9286CV-8e RAID card; however, customers should contact

 

their storage vendor for technical support related to enclosure/JBOD.

 

 

 

 

Includes an chassis-mount (remote) supercapacitor to power on-board

 

1 GB flash-backed write cache.

 

Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID

 

Configuration section in this table). Note that factory RAID configuration is

 

not available for these controllers, because the factory does not control

 

the storage array attached to them.

 

 

 

 

Super Capacitor Option

 

 

 

 

 

 

UCS-RAID-CV-SC=

LSI CacheVault Power Module. This is a spare supercapacitor. It is the exact

 

same supercapacitor that ships with the 9271CV-8i, 9285CV-8e, and 9286CV-8e

 

cards listed earlier in this table and can be used as a replacement or upgrade

 

part.

RAID Configuration Options (not available for embedded RAID)

R2XX-SRAID0

Enable Single Disk Raid 0 Setting (for the following PIDs only):

 

UCS-RAID9271-8i or UCS-RAID9271CV-8I

 

UCSC-RAID-11-C220

 

UCSC-RAID-MZ-220

R2XX-RAID0

Factory preconfigured RAID striping option

 

Enable RAID 0 Setting. Requires a minimum of one hard drive.

R2XX-RAID1

Factory preconfigured RAID mirroring option

 

Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,

 

capacity.

R2XX-RAID5

Factory preconfigured RAID option

 

Enable RAID 5 Setting. Requires a minimum of three drives of the same size,

 

speed, capacity.

R2XX-RAID6

Factory preconfigured RAID option

 

Enable RAID 6 Setting. Requires a minimum of four drives of the same size,

 

speed, capacity.

R2XX-RAID10

Factory preconfigured RAID option

 

Enable RAID 10 Setting. Requires a even number of drives (minimum of four

 

drives) of the same size, speed, capacity.

 

 

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

25

Image 25
Contents SAN JOSE, CA REV C.18 December 17 Spec SheetStep Step Verify Server SKUContents Page Overview Shows the Cisco UCS C220 M3 High-Density SFF Rack Server Chassis Front ViewChassis Rear View Shows the external features of the rear panelChassis One rack unit 1RU chassis Capabilities and Features Capability/Feature DescriptionCPU NICCapability/Feature Description Acpi Configuring the Server Verify the product ID PID of the server as shown in Table Verify Server SKUCards, with 1 rail kit DDR3 Dimm Select CPUsProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Select any one CPU listed in Table Approved Configurations CPU configurationsSelect two identical CPUs from any one of the rows of on CaveatsC220 M3 SFF Memory Organization Select MemoryDimm Select DIMMs and Memory MirroringDimm Options Memory Mirroring OptionA1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2 CPU configuration with memory mirroringA1, B1 E1, F1 A1,B1 C1,D1 DPC Dimm Memory SpeedsConfiguring the Server Select RAID Configuration Available Embedded RAID Options Select RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-MZ-220 UCSC-RAID-11-C220Available PCIe RAID Controller Options RAID Configuration Options not available for embedded RAIDSuper Capacitor Option Approved Configurations RAID4 RAID RAID1Caveats HDDs Select DrivesSSDs You can mix Sata and SAS drives Network Interface Cards NICs Select PCIe Option CardsHost Bus Adapters HBAs UCS Storage Accelerators Approved Configurations No PCIe RAID controllerOne PCIe RAID controller Configuring the Server Choose Optional Twinax Cables Order Optional Network Card AccessoriesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Preinstalled do not change SFPCisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Power Supply PIDs Order Power SupplyUCSC-PSU-450W UCSC-PSU-650WR2XX-DMYMPWRCORD Available Power Cords Product ID PID PID Description ImagesCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-EU CAB-9K10A-AUAvailable Power Cords Product ID PID PID Description Cable Management Arm Order Optional Reversible Cable Management ARMUCSC-CMA1 Cable Management Arm for C220 rack serversTrusted Platform Module Product ID PID PID Description Order a Trusted Platform Module OptionalUCSX-TPM1-001 Trusted Platform Module Secure Digital SD Card preloaded with software Order Cisco Flexible Flash SD Card Module OptionalSecond Secure Digital SD Card blank UCS-SD-16GOrder Optional USB 2.0 Drive See on page 57 for the location of the USB connectorUSB 2.0 Drive UCS-USBFLSH-S-4GBSuse Select Operating System and VALUE-ADDED SoftwareNexus 1000V for Hyper-V and vSphere BMCUCS Director Configuring the Server OS Media Product ID PID PID Description Select Operating System Media KITCisco SMARTnet for UCS Service Unified Computing Warranty, No ContractSMARTnet for UCS Product ID PID On Site? DescriptionUCS HW 24X7X4OS UCS C220 M3 SFF CON-UCW7-C220M3SFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFService Product ID PID Level Description Site? Partner Support Service for UCSUnified Computing Combined Support Service GSPUCS DR UCSD7 UCSD7CON-UCWD7-C220M3SF UCWD7UCWD5 CON-UCWD5-C220M3SFRacks and Rack Options Product ID PID PID Description RP208-30-2P-U-2 Zero RU PDU PDU OptionsFor more information about the PDU, see PDUs, Supplemental Material Physical Layout CPUs and DIMMsCPU1 DPC or 2 DPC Memory Population RulesDPC DIMMs per Channel DPCPopulate the DIMMs for a CPU according to Table Dimm Population OrderRecommended Memory Configuration Supported Dimm Populations Supported Dimm Configurations Total DIMMsCPU TotalLow-Voltage Dimm Considerations CPU Configurations Select one of the following Available RAID configurations are shown in this sectionRAID Details Example Bios Screen for Oprom RAID Option ROM Oprom SettingsSerial Port Details Serial Port Female RJ-45 Connector PinoutUpgrade and Servicing-Related Parts CPU Removal and Installation pick n place Tool Set Motherboard Lithium BatteryDrive Blanking Panels Adding an Additional CPU with CPU heat sinkCPU Heat Sink Cleaning Kit Air Baffle Replacement KitRacks Cisco R42610 Rack Zero Rack Unit PDU PID = RP208-30-2P-U-2 PDUsN20-BKVM KVM Cable Product ID PID PID DescriptionKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location Power Specifications Dimensions and WeightUCS C220 M3 Dimensions and Weight Parameter Value Technical Specifications Input Class RSP1Output UCS C220 M3 Environmental Specifications Parameter Minimum Environmental SpecificationsCISPR24 Compliance RequirementsEN300386 KN24
Related manuals